[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

Maintaining the Host Subsystem

The host subsystem comprises a Routing Engine installed directly into an SCB. To maintain the host subsystem components, follow these guidelines:

To check the status of a specific SCB, issue the show chassis environment cb command and include the slot number of the SCB. The output is similar to the following:


user@host> show chassis environment cb 0
CB 0 status:
  State                      Online
  Temperature Intake         66 degrees C / 150 degrees F
  Temperature Exhaust A      67 degrees C / 152 degrees F
  Temperature Exhaust B      73 degrees C / 163 degrees F
  Power
    1.2 V                     1153 mV
    1.5 V                     1417 mV
    1.8 V                     1704 mV
    2.5 V                     2375 mV
    3.3 V                     3138 mV
    5.0 V                     4763 mV
    1.2 V Rocket IO           1160 mV
    1.5 V Rocket IO           1408 mV
    1.8 V RLDRAM              1717 mV
  I2C Slave Revision         15

For more information about using the CLI, see the JUNOS software manuals.