[ Contents] [ Prev] [ Next] [ Report an Error]

Install the Device Using a Lift

  1. Ensure the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance. For details, see the SRX 5600 Services Gateway Hardware Guide.
  2. Load the device onto the lift, making sure it rests securely on the lift platform (see Figure 4).

    Figure 4: Load the Device onto the Lift

    Image g004247.gif

  3. Using the lift, position the device in front of the rack or cabinet, centering it in front of the mounting shelf.
  4. Lift the chassis approximately 0.75 in. above the surface of the mounting shelf and position it as close as possible to the shelf.
  5. Carefully slide the device onto the mounting shelf so that the bottom of the chassis and the mounting shelf overlap by approximately two inches.
  6. Slide the chassis onto the mounting shelf until the mounting brackets contact the rack rails. The shelf ensures that the holes in the mounting brackets and the front-mounting flanges of the chassis align with the holes in the rack rails.
  7. Move the lift away from the rack.
  8. Install a mounting screw into each of the open mounting holes aligned with the rack, starting from the bottom.
  9. Visually inspect the alignment of the device. If the device is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side and the device should be level.

[ Contents] [ Prev] [ Next] [ Report an Error]