[ Contents] [ Prev] [ Next] [ Report an Error]

Installing an SCB

To install an SCB (see Figure 3):

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see Preventing Electrostatic Discharge Damage.
  2. If you have not already done so, power off the device as described in Powering Off the Services Gateway.
  3. Carefully align the sides of the SCB with the guides inside the chassis.
  4. Slide the SCB into the chassis until you feel resistance, carefully ensuring that it is correctly aligned.
  5. Grasp both ejector handles and rotate them simultaneously clockwise until the SCB is fully seated.
  6. Place the ejector handles in the proper position, horizontally and toward the center of the board.
  7. Switch the circuit breaker or toggle switch for each power supply to the ON position to start the device. The OK LED on the power supply faceplate should blink, then light steadily.

    For detailed instructions on powering-on the device see the SRX 5600 Services Gateway Hardware Guide or the SRX 5800 Services Gateway Hardware Guide.

  8. To verify that the SCB is functioning normally, check the LEDs on its faceplate. The green OK/FAIL LED should light steadily a few minutes after the SCB is installed. If the OK/FAIL LED is red, remove and install the SCB again (see Removing an SCB and Installing an SCB). If the OK/FAIL LED still lights steadily, the SCB is not functioning properly. Contact your customer support representative.

    To check the status of the SCB:


    user@host> show chassis environment cb
    CB 0 status:
      State                      Online Master
      Temperature                30 degrees C / 86 degrees F
      Power 1
        1.2 V                     1202 mV
        1.5 V                     1511 mV
        1.8 V                     1798 mV
        2.5 V                     2481 mV
        3.3 V                     3306 mV
        5.0 V                     4956 mV
        12.0 V                   12084 mV
        1.25 V                    1250 mV
        3.3 V SM3                 3287 mV
        5.0 V RE                  5046 mV
        12.0 V RE                11910 mV
      Power 2
        11.3 V bias PEM          11292 mV
        4.6 V bias MidPlane       4833 mV
        11.3 V bias FPD          11156 mV
        11.3 V bias POE 0        11253 mV
        11.3 V bias POE 1        11272 mV
      Bus Revision               42
      FPGA Revision              1
    CB 1 status:
      State                      Online
      Temperature                31 degrees C / 87 degrees F
      Power 1
        1.2 V                     1205 mV
        1.5 V                     1508 mV
        1.8 V                     1817 mV
        2.5 V                     2507 mV
        3.3 V                     3306 mV
        5.0 V                     5053 mV
        12.0 V                   12200 mV
        1.25 V                    1256 mV
        3.3 V SM3                 3306 mV
        5.0 V RE                  5091 mV
        12.0 V RE                    0 mV
      Power 2
        11.3 V bias PEM          11214 mV
        4.6 V bias MidPlane       4821 mV
        11.3 V bias FPD          11350 mV
        11.3 V bias POE 0        11350 mV
        11.3 V bias POE 1        11330 mV
      Bus Revision               42
      FPGA Revision              0

Figure 3: Installing an SCB

Image g004049.gif


[ Contents] [ Prev] [ Next] [ Report an Error]