
J Series Services Routers Hardware Guide
Copyright and Trademark Information
Table of Contents
About This Guide
Services Router Overview 
Overview of Services Routers
J Series Services Router Hardware Features
PIM Overview
PIM Terms
Field-Replaceable PIMs
J2320 and J2350 Field-Replaceable PIM and Module Summary
J4350 and J6350 Field-Replaceable PIM Summary
1-Port, 6-Port, 8-Port, and 16-Port Gigabit Ethernet uPIMs
1-Port Gigabit Ethernet ePIMs
Dual-Port Serial PIM
Dual-Port T1 or E1 PIM
Dual-Port Channelized T1/E1/ISDN PRI PIM
T3 or E3 PIM
Dual-Port Fast Ethernet PIM
4-Port Fast Ethernet ePIM
4-Port ISDN BRI PIMs
ADSL PIM
G.SHDSL PIM 
Installing a Services Router
Preparing for Router Installation
Installing and Connecting a Services Router
Establishing Basic Connectivity
Basic Connectivity Terms
Basic Connectivity Overview
Before You Begin
Connecting to a Services Router
Configuring Basic Settings with J-Web
Configuring Basic Settings Using the CLI Configuration Wizard
Configuring Basic Settings with a Configuration Editor
Verifying Basic Connectivity and the Configuration
Installing JUNOS Software
Maintaining Services Router Hardware
Replacing Hardware Components
Tools and Parts Required
Replacing the Console Port Cable
Replacing a PIM
Replacing PIM Cables
Removing and Replacing the Chassis Cover on J2320 and J2350
Routers
Replacing Internal Compact Flashes on J2320 and J2350 Routers
Replacing Internal Compact Flashes on J4350 and J6350 Routers
Replacing External Compact Flashes
Replacing USB Storage Devices
Replacing DRAM Modules
Replacing Power System Components
Replacing Crypto Accelerator Modules on J2320 and J2350 Routers
Replacing Crypto Accelerator Modules on J4350 and J6350 Routers
Replacing Air Filters on J2350 Routers
Replacing Air Filters on J4350 and J6350 Routers
Troubleshooting a Services Router
Contacting Customer Support and Returning Hardware
J Series Requirements and Specifications
Network Cable Specifications and Connector Pinouts
Serial PIM Cable Specifications
Fast Ethernet RJ-45 Connector Pinout
Gigabit Ethernet uPIM RJ-45 Connector Pinout
Gigabit Ethernet ePIM RJ-45 Connector Pinout
Chassis Console Port Pinouts
E1 and T1 RJ-48 Cable Pinouts
E3 and T3 BNC Connector Pinout
ADSL and G.SHDSL RJ-11 Connector Pinout
ISDN RJ-45 Connector Pinout
Safety and Regulatory Compliance Information
Definition of Safety Warning Levels
Safety Guidelines and Warnings
General Safety Guidelines and Warnings
Electrical Safety Guidelines and Warnings
General Electrical
Safety Guidelines
AC Power Electrical Safety Guidelines
DC Power Electrical Safety
Guidelines
Power Sources for Redundant Power Supplies
DC Power Disconnection
Warning
DC Power
Grounding Requirements and Warning
DC Power Wiring Sequence Warning
DC Power Wiring Terminations Warning
Grounded Equipment Warning
Warning Statement for Norway and Sweden
In Case
of Electrical Accident
Multiple Power Supplies Disconnection Warning
Power
Disconnection Warning
TN Power Warning
Telecommunication Line Cord Warning
Installation Safety Guidelines and Warnings
Laser and LED Safety Guidelines and Warnings
Maintenance and Operational Safety Guidelines and Warnings
Agency Approvals
Compliance Statements for Environmental Requirements
Compliance Statements for EMC Requirements
IndexSymbols
A
- AC plug types
- AC power
- connecting power
- cords See AC power cords
- dedicated AC power feed requirement
- electrical specifications 1, 2
- grounding the router
- installing a J6350 power supply
- J2320 system
- J2350 system
- J4350 system
- J6350 system
- removing a J6350 power supply
- requirements
- safety guidelines
- AC power cords
- accident, steps to take
- ACTIVITY LED (Dual-Port Fast Ethernet PIM)
- adapter, console port
- adapters, for compact flash recovery
- addresses
- ADSL PIM
- ADSL ports
- agency approvals
- air filter
- airflow
- ALARM LED
- description 1, 2
- indications
- alarms
- alternative boot media See boot devices; USB
- altitude requirement
- Annex A; Annex B See ADSL; SHDSL
- antistatic mat
- approvals, agency
- asymmetric digital subscriber line See ADSL
- AT modem command 1, 2
- AT&D1 modem command
- AT&K0 modem command
- AT&W modem command
- ATDT modem command
- ATS0=1 modem command
- AUX port 1, 2
- auxiliary console port 1, 2
B
- backup compact flash, removing
- backup router
- basic connectivity
- battery
- blank panel
- blinking
- Fast Ethernet port ACTIVITY LED state (dual-port PIM)
- Fast Ethernet port link activity LED state (4-port ePIM)
- Gigabit Ethernet port LED
- Gigabit Ethernet port TX/RX LED state 1, 2, 3
- ISDN BRI ONLINE LED state
- POWER LED state 1, 2
- STATUS (router) LED state 1, 2
- boot devices 1, 2
- boot process, backup router for
- boot sequence 1, 2
- braces, in configuration statements
- brackets
- BTUs per hour
- built-in Ethernet ports See Gigabit Ethernet ports
- buttons
- power 1, 2
- RESET CONFIG
C
- cables
- AC power See AC power cords
- ADSL RJ-11 pinouts
- arranging for safety
- chassis console port, DB-9 connector pinouts
- chassis console port, RJ-45 connector pinouts
- connecting to network media
- console port cable (chassis), connecting 1, 2
- console port cable (chassis), replacing
- console port, connecting
- DC cables See DC power cables
- disconnecting PIM cables
- E1 RJ-48 pinouts
- Ethernet cable, connecting 1, 2, 3
- Ethernet rollover, connecting
- Fast Ethernet RJ-45 connector pinout
- Gigabit Ethernet RJ-45 connector pinouts (ePIM)
- Gigabit Ethernet RJ-45 connector pinouts (uPIMs)
- grounding
- ISDN RJ-45 pinouts
- PIM, installing
- PIM, removing
- reducing radio frequency interference (RFI)
- serial EIA-530A DCE pinouts
- serial EIA-530A DTE pinouts
- serial PIM specifications
- serial RS-232 DCE pinouts
- serial RS-232 DTE pinouts
- serial RS-422/449 (EIA-449) DCE pinouts
- serial RS-422/449 (EIA-449) DTE pinouts
- serial V.35 DCE pinouts
- serial V.35 DTE pinouts
- serial X.21 DCE pinouts
- serial X.21 DTE pinouts
- SHDSL RJ-11 pinouts
- T1 RJ-48 pinouts
- Canada, compliance statement
- case number, for JTAC
- channelized E1 PIM
- channelized E1 ports
- channelized T1 PIM
- channelized T1 ports
- chassis
- alarm conditions and remedies 1, 2
- component serial number labels 1, 2
- cover, replacing (J2320 and J2350)
- dimensions 1, 2
- environmental tolerances
- grounding
- heat dissipation
- J2320
- J2350
- J4350
- J6350
- lifting guidelines
- PIM slot numbers 1, 2
- power consumption
- power management, planning
- power management, troubleshooting
- rack requirements
- weight 1, 2
- checklist, for site preparation
- clear operation, RESET CONFIG button
- clear-text access
- clearance
- CLI configuration editor
- comments, in configuration statements
- committed configuration
- compact flash
- backup, replacing
- description 1, 2
- external, description
- external, J2320 and J2350
- external, replacing
- inserting
- internal, recovering
- location (horizontal)
- location (vertical)
- minor (yellow) alarm
- recovering, See also compact flash recovery
- removing
- replacing 1, 2
- replacing, rotating fans warning 1, 2
- compact flash recovery
- compliance
- components
- packing for shipment
- replacing
- serial number label 1, 2
- troubleshooting, See also LEDs
- configuration
- configuration editor See CLI configuration editor; J-Web configuration editor
- connection
- connectivity
- basic See basic connectivity
- hardware
- modem (remote) connection
- through J-Web
- through the CLI locally
- through the CLI remotely
- console port
- adapter
- adapter (chassis) 1, 2
- auxiliary console port 1, 2
- connecting through the CLI locally
- connecting through the CLI remotely
- description 1, 2
- on chassis, DB-9 connector pinouts
- on chassis, RJ-45 connector pinouts
- replacing the cable
- settings for local CLI connection
- settings for modem connection at router for remote CLI access
- settings for modem connection for remote CLI access
- conventions
- cooling system
- airflow requirement
- description 1, 2
- Copper Gigabit Ethernet ePIMs
- Copper Gigabit Ethernet uPIMs
- cords See AC power cords; cables; DC power cables
- cover, replacing (J2320 and J2350)
- Crypto Accelerator Module
- curly braces, in configuration statements
- customer support 1
- Cygwin, for compact flash recovery
D
- datasheets URL
- DB-9 connector pinouts
- DB-9 to DB-25 serial port adapter
- DC power
- cables See DC power cables
- connecting power
- dedicated DC power feed requirement
- electrical specifications 1, 2
- grounding requirements and warning
- grounding the router
- installing a J6350 power supply
- J2320 system
- J2350 system
- J4350 system
- J6350 system
- power disconnection warning
- removing a J6350 power supply
- requirements
- safety guidelines (general)
- safety guidelines, power sources for redundant power supplies
- wiring sequence warning
- wiring terminations warning
- DC power cables
- dd utility, for compact flash recovery
- Declaration of Conformity
- default gateway
- DHCP (Dynamic Host Configuration Protocol)
- DHCP server
- diagnosis
- dial-up modem connection See modem connection to router console port
- digital certificate See SSL certificates
- digital subscriber line See ADSL; SHDSL
- DIMMs (dual inline memory modules) See DRAM modules
- DNS (Domain Name System)
- DNS server
- documentation
- domain name 1, 2, See also DNS server
- Domain Name System
- domain search
- DRAM modules
- dry chemical fire extinguishers, prohibited
- DS1 ports See E1 ports; T1 ports
- DS3 ports See E3 ports; T3 ports
- DSL See ADSL; SHDSL
- dual inline memory modules See DRAM modules
- Dual-Port Channelized T1/E1/ISDN PRI PIM
- Dual-Port E1 PIM
- Dual-Port E3 PIM
- Dual-Port Fast Ethernet PIM
- Dual-Port Serial PIM
- Dual-Port T1 PIM
- Dual-Port T3 PIM
E
- E1 ports
- description, See also channelized E1 ports
- LED states
- RJ-48 cable pinouts
- E3 ports
- earth ground See grounding
- earthquakes
- EIA-530A DCE cable pinouts
- EIA-530A DTE cable pinouts
- electrical specifications
- electricity
- electromagnetic compatibility (EMC) See EMC
- electromagnetic interference (EMI) See See EMI
- electrostatic bag, for storing components
- electrostatic discharge, preventing
- EMC (electromagnetic compatibility)
- EMI (electromagnetic interference)
- encrypted access
- environmental requirements for operation
- ePIMs
- EPROM 1, 2
- ESD (electrostatic discharge), preventing
- ESD wrist strap
- Ethernet cable
- chassis console DB-9 connector pinouts
- chassis console, RJ-45 connector pinouts
- connecting the Services Router to a management device 1, 2
- connecting the Services Router to a modem
- replacing
- Ethernet ports See Fast Ethernet ports See Gigabit Ethernet ports
- Ethernet rollover cable, connecting the router to a management device
- European Union, compliance statement
- external compact flash See compact flash
F
- failures
- compact flash, USB for 1, 2
- PIM, troubleshooting
- Routing Engine fan, troubleshooting
- fans
- description 1, 2, See also air filter See also cooling system
- failure, troubleshooting
- Fast Ethernet ports
- FCC Part 15 compliance statement
- FCC Part 68 compliance statement
- field-replaceable units, replacing
- filter cover See air filter
- filter, air See air filter
- fire extinguishers
- fire safety requirements
- fire suppression
- font conventions
- FPC, PIM slot number in command displays 1, 2
- front panel 1, 2, 3
- FRUs (field-replaceable units), replacing
G
- G.SHDSL PIM
- G.SHDSL ports See SHDSL ports
- gateway, default
- ge-0/0/0
- Gigabit Ethernet ePIMs
- Gigabit Ethernet ports
- Gigabit Ethernet uPIMs
- glossary
- graceful shutdown
- grounding
- grounding lug
- gzip utility, for compact flash recovery
H
- HA (high availability) LED
- hardware
- hardware features
- components
- front panel 1, 2, 3
- PIMs
- product overview
- Hayes-compatible modem See modem connection to router console port
- heat dissipation, PIMs
- high-speed interfaces See ePIMs
- high-speed slots for ePIMs, location
- hostname 1, See also DNS server
- humidity requirement
- Hyperterminal, for terminal emulation
I
- immunity standards
- initial configuration requirements
- injury, steps to take
- installation
- AC power supplies (J6350)
- air filter
- compact flash 1, 2
- console port cable (chassis)
- Crypto Accelerator Module 1, 2
- DC power supplies (J6350)
- DRAM modules
- initial
- PIM cables
- PIMs
- preparation
- requirements
- restricted access, J2350
- restricted access, J4350 and J6350 1, 2, 3, 4
- safety guidelines and warnings
- site checklist
- site guidelines
- USB storage device
- Integrated Services Digital Network See ISDN
- interfaces
- ISDN BRI ports
- ISDN PRI PIM
- ISDN provisioning, See also ISDN BRI ports
J
- J Series
- J-Web configuration editor
- J-Web interface
- configuration editor See J-Web configuration editor
- connecting
- Quick Configuration See Quick Configuration
- J-Web Quick Configuration See Quick Configuration
- J2320
- boot devices
- boot sequence
- chassis
- chassis cover, replacing
- compact flash location
- compact flash, replacing
- cooling system
- electrical specifications
- external compact flash
- fans
- front panel 1, 2
- hardware 1, 2
- installation
- interfaces supported
- mounting brackets
- overview
- physical specifications
- PIMs supported
- ports supported
- power management
- Routing Engine, hardware
- USB port
- J2350
- air filter, replacing
- boot devices
- boot sequence
- chassis
- chassis cover, replacing
- compact flash location
- compact flash, replacing
- cooling system
- electrical specifications
- external compact flash
- fans
- front panel 1, 2
- hardware 1, 2
- installation
- interfaces supported
- mounting brackets
- overview
- physical specifications
- PIMs supported
- ports supported
- power management
- power system
- restricted access installation
- Routing Engine, hardware
- USB port
- J4350
- 4-Port Fast Ethernet ePIM
- 4-Port ISDN BRI S/T PIM
- 4-Port ISDN BRI U PIM
- ADSL PIM
- air filter, replacing
- boot devices
- boot sequence
- chassis
- cooling system
- Dual-Port Channelized T1/E1/ISDN PRI PIM
- Dual-Port E1 PIM
- Dual-Port Fast Ethernet PIM
- Dual-Port Serial PIM
- Dual-Port T1 PIM
- electrical specifications
- fans
- front panel
- FRUs, replacing
- G.SHDSL PIM
- Gigabit Ethernet ePIM
- Gigabit Ethernet uPIMs
- hardware
- hardware components
- hardware, replacing
- installation
- interfaces supported
- mounting brackets, installing
- overview
- physical specifications
- PIM overview
- PIMs supported
- ports supported
- power management
- power system
- restricted access installation 1, 2, 3, 4
- Routing Engine, hardware
- USB port
- J6350
- 4-Port Fast Ethernet ePIM
- 4-Port ISDN BRI S/T PIM
- 4-Port ISDN BRI U PIM
- ADSL PIM
- air filter, replacing
- boot devices 1, 2
- boot sequence
- chassis
- cooling system
- Dual-Port Channelized T1/E1/ISDN PRI PIM
- Dual-Port E1 PIM
- Dual-Port Fast Ethernet PIM
- Dual-Port Serial PIM
- Dual-Port T1 PIM
- E3 PIM
- electrical specifications
- fans
- front panel
- FRUs, replacing
- G.SHDSL PIM
- Gigabit Ethernet ePIM
- Gigabit Ethernet uPIMs
- hardware
- hardware components
- hardware, replacing
- installation
- interfaces supported
- mounting brackets, installing
- overview
- physical specifications
- PIM overview
- PIMs supported
- ports supported
- power management
- power supplies See power supplies, J6350
- restricted access installation 1, 2, 3, 4
- Routing Engine, hardware
- T3 PIM
- USB port
- Japan, compliance statement
- JTAC (Juniper Networks Technical Assistance Center)
- Juniper Networks Technical Assistance Center See JTAC
- JUNOS CLI
- JUNOS Software
- JUNOScript API
L
- labels, serial number 1, 2
- laptop See management device
- lasers
- LEDs
- ACTIVITY status (dual-port PIM)
- ADSL PIM status
- ADSL port status
- ALARM 1, 2
- channelized E1 ports
- channelized T1 ports
- Class 1 product warning
- E1 port status
- E3 port status
- Fast Ethernet port status (4-port ePIM)
- Fast Ethernet port status (dual-port PIM) 1, 2
- G.SHDSL PIM status
- Gigabit Ethernet port status 1, 2, 3
- HA 1, 2
- ISDN PIM status 1, 2
- ISDN port status
- J4350 power supply
- J6350 power supply
- LAN port status 1, 2
- LINK 1, 2, 3
- link activity (4-Port Fast Ethernet ePIM)
- link status (4-port ePIM)
- LINK/ SPEED status (Dual-Port Fast Ethernet PIM)
- ONLINE status (ADSL PIM)
- ONLINE status (G.SHDSL PIM)
- ONLINE status (ISDN BRI PIMs)
- POWER 1, 2
- safety warnings
- serial port status
- SHDSL port status
- STATUS (router) 1, 2
- T1 port status
- T3 port status
- TX/RX 1, 2, 3
- LH transceiver
- lifting guidelines
- lightening activity warning
- limitations
- link activity LED (4-Port Fast Ethernet ePIM)
- LINK LED 1, 2, 3
- link status LED (4-Port Fast Ethernet ePIM)
- LINK/ SPEED LED (Dual-Port Fast Ethernet PIM)
- lithium battery compliance
- lo0.0
- local connection to the router console port
- loopback address
- LX transceiver
M
- maintenance
- AC power cord, replacing
- air filter
- console port cable (chassis)
- Crypto Accelerator Module 1, 2
- DC power cable, replacing
- DRAM modules
- external compact flash
- internal compact flash 1, 2
- PIM cables
- PIMs
- power system
- tools and parts required
- USB storage device
- warnings
- major (red) alarms
- management access
- management device
- connecting through the CLI 1, 2
- connecting to console port
- connecting to J-Web 1, 2
- recovering root password from
- management interface address
- management interfaces
- management ports 1, 2, See also management interface address; management interfaces
- manuals
- memory See compact flash; DRAM modules; USB
- midplane 1, 2
- minor (yellow) alarms
- modem commands
- modem connection to router console port
- monoammonium phosphate
- mounting brackets
- multiple routers
N
- NEBS (Network Equipment Building System)
- identifying NEBS-compliant routers
- shutdown temperature for NEBS-compliant routers 1, 2
- network cable pinouts
- Network Equipment Building System See NEBS
- Network Time Protocol (NTP) server See NTP server
- Norton Ghost utility, for compact flash recovery
- notice icons
- NT1 device, provisioning information
- NTP server
O
P
- packing materials
- parentheses, in syntax descriptions
- password See root password
- passwords
- PC See management device
- personnel warning
- physdiskwrite utility, for compact flash recovery
- PIC See PIMs
- PIM number, always 0
- PIMs (Physical Interface Modules)
- 4-Port Fast Ethernet
- 4-Port ISDN BRI
- ADSL
- cables and connectors
- Dual-Port Channelized T1/E1/ISDN PRI PIM
- Dual-Port E1
- Dual-Port Fast Ethernet
- Dual-Port Serial
- Dual-Port T1
- E3
- failure
- field-replaceable PIMs
- G.SHDSL
- Gigabit Ethernet ePIMs
- Gigabit Ethernet uPIMs
- heat dissipation
- installing
- installing cables
- LEDs See LEDs
- major (red) alarm
- midplane to Routing Engine 1, 2
- non-hot-swappability 1, 2, 3
- offline, troubleshooting
- overview
- PIM number, always 0 1, 2
- power consumption
- power management, planning
- power management, troubleshooting
- removing
- replacing cables
- serial number label
- slot numbering, J2320 and J2350
- slot numbering, J4350 and J6350
- T3
- pinouts
- ADSL RJ-11 connector
- chassis console DB-9 connector
- chassis console port
- EIA-530A DCE serial cable
- EIA-530A DTE serial cable
- Fast Ethernet connector
- Gigabit Ethernet connector (ePIM)
- Gigabit Ethernet connector (uPIMs)
- ISDN RJ-45 connector
- RJ-45 chassis console connector
- RJ-48 connector to DB-15 connector (crossover)
- RJ-48 connector to DB-15 connector (straight)
- RJ-48 connector to RJ-48 connector (crossover)
- RJ-48 connector to RJ-48 connector (straight)
- RS-232 DCE serial cable
- RS-232 DTE serial cable
- RS-422/449 (EIA-449) DCE serial cable
- RS-422/449 (EIA-449) DTE serial cable
- SHDSL RJ-11 connector
- V.35 DCE serial cable
- V.35 DTE serial cable
- X.21 DCE serial cable
- X.21 DTE serial cable
- plug types, AC
- ports
- 0
- ADSL See ADSL ports
- AUX 1, 2
- cables, PIM, installing
- cables, WAN, removing
- channelized See channelized E1 ports; channelized T1 ports
- console (chassis) 1, 2, See also console port
- DS1 See E1 ports; T1 ports
- DS3 See E3 ports; T3 ports
- E1 See E1 ports
- E3 See E3 ports
- G.SHDSL See SHDSL ports
- interface naming
- ISDN See ISDN BRI ports
- J2320 types supported
- J2350 types supported
- J4350 types supported
- J6350 types supported
- lo0.0
- serial See serial ports
- SHDSL See SHDSL ports
- T1 See T1 ports
- T3 See T3 ports
- USB 1, 2
- power
- AC power See AC power
- applying
- button 1, 2
- connecting
- consumption, PIMs
- DC power See DC power
- grounding requirement
- LED 1, 2
- managing
- power cables See DC power cables
- power cords See AC power cords
- power supplies See power supplies
- power system See power system
- removing
- requirements
- troubleshooting
- power button 1, 2
- power cables See DC power cables
- power cords See AC power cords
- POWER LED 1, 2
- power management
- power supplies
- J2320
- J2350
- J4350
- J6350 See power supplies, J6350
- LED states
- power supplies, J6350
- power system
- preparing for installation
- product disposal
- product overview
- provisioning an ISDN line
Q
- Quick Configuration
R
- rack installation
- general requirements
- lifting guidelines
- mounting brackets
- order of multiple routers 1, 2
- procedure 1, 2
- safety guidelines and warnings
- securing rack to building
- size requirements 1, 2
- support for front-mount rack 1, 2
- ventilation requirement 1, 2
- radio frequency interference (RFI), reducing
- ramp angle requirement
- read or write error, Routing Engine
- recovering compact flash See compact flash recovery
- red alarms See major alarms
- redundant J6350 power supplies
- regulatory compliance
- remote connection to router console port
- replacement
- AC power cord
- air filter
- console port cable (chassis)
- Crypto Accelerator Module 1, 2
- DC power cable
- DRAM modules
- external compact flash
- internal compact flash 1, 2
- PIM cables
- PIMs
- power system (J6350)
- tools and parts required
- USB storage device
- request chassis pic fpc-slot command
- reset
- power button for restart 1, 2
- RESET CONFIG button for factory configuration
- RESET CONFIG button
- Return Materials Authorization See RMA
- returning hardware 1
- RJ-45 connector pinouts
- RJ-45 to DB-9 serial port adapter 1
- RJ-48 connector to DB-15 connector (crossover) pinouts
- RJ-48 connector to DB-15 connector (straight) pinouts
- RJ-48 connector to RJ-48 connector (crossover) pinouts
- RJ-48 connector to RJ-48 connector (straight) pinouts
- RMA (Return Materials Authorization) 1
- rollover cable, connecting the console port
- root password
- root password recovery
- router See Services Router
- Routing Engine
- RS-232 DCE cable pinouts
- RS-232 DTE cable pinouts
- RS-422/449 (EIA-449) DCE cable pinouts
- RS-422/449 (EIA-449) DTE cable pinouts
S
- S/T port See ISDN BRI ports
- safety guidelines and warnings
- AC power
- battery handling
- DC power (general)
- DC power disconnection
- DC power wiring sequence warning
- DC power wiring terminations warning
- DC power, grounding requirements and warning
- DC power, redundant power supplies
- electrical
- general
- grounded equipment
- in case of electrical accident
- installation
- jewelry removal
- lasers and LEDs
- levels
- lightening activity
- maintenance and operation
- multiple power supplies
- operating temperature
- power disconnection
- product disposal
- rack-mounting
- ramps
- read installation instructions
- telecommunications cord
- TN power system
- safety standards 1
- sample configuration
- serial number
- chassis components, label 1, 2
- PIMs
- power supply
- serial ports
- service provider, contacting for ISDN provisioning
- Services Router
- backup
- clearance
- connecting
- establishing software connectivity
- grounding a DC-powered model
- grounding an AC-powered model
- hardware replacement
- hardware return
- installation and connection
- network cables and connectors
- operating environment
- overview
- packing for shipment
- PIM overview
- powering on and off
- preparation checklist
- safety and compliance
- site preparation
- unpacking
- Set Up page
- setup
- SFP Gigabit Ethernet ePIMs
- SFP Gigabit Ethernet uPIMs
- SHDSL ports
- shipping carton
- show chassis alarms command
- show chassis fpc pic-status command
- show chassis hardware command
- identifying NEBS-compliant routers
- locating component serial numbers
- verifying Crypto Accelerator Module installation 1, 2
- show chassis power-ratings command
- show chassis routing-engine command
- checking CPU temperature 1, 2
- checking DRAM amount 1, 2
- verifying DRAM installation and configuration
- shutdown
- shutdown temperature
- NEBS-compliant routers 1, 2
- non-NEBS-compliant routers
- signaling limitations
- site preparation
- size
- slot numbers, PIM
- chassis diagram 1, 2
- displayed as FPC number in command output
- small form-factor pluggable transceivers See SFP
- SNMP (Simple Network Management Protocol), no Gigabit Ethernet support 1, 2
- specifications
- SSH
- standards compliance
- startup
- status
- STATUS LEDs
- storage media
- recovering internal compact flash
- replacing the external compact flash
- replacing the internal compact flash 1, 2
- replacing the USB storage device
- support, technical See technical support
- SX transceiver
- symmetric high-speed digital subscriber line See SHDSL
- syntax conventions
- system time
T
- T1 ports
- description, See also channelized T1 ports
- LED states
- RJ-48 cable pinouts
- T3 ports
- technical support
- telecommunications line wire gauge
- Telnet
- temperature
- required for operation
- Routing Engine, too warm
- shutdown, NEBS-compliant routers 1, 2
- shutdown, non-NEBS-compliant routers
- warning
- temperature alarm, air filter replacement for
- terminology
- thermal output
- time See system time
- time zone 1
- TN power system
- tolerances, environmental
- tools and equipment
- troubleshooting
- troubleshooting a Services Router, hardware components
- turning on a Services Router
- TX/RX LED 1, 2, 3
- Type C fire extinguishers
U
- U port See ISDN BRI ports
- United States, compliance statements
- universal serial bus See USB
- unpacking the router
- uPIMs, Gigabit Ethernet See Gigabit Ethernet uPIMs
- URLs
- USB (universal serial bus)
- utilities, for compact flash recovery
V
W
- warnings
- battery handling
- DC power cables
- DC power disconnection
- DC power plant and chassis ground
- DC wiring sequence
- DC wiring terminations
- DC-powered J4350 and J6350 routers, restricted access installation only
- earthed mains socket (Norway and Sweden only)
- electrical
- ESD strap to prevent router damage
- follow lifting guidelines 1, 2
- general
- grounded equipment
- installation
- jewelry removal
- laser and LED
- levels defined
- lightening activity
- maintenance and operational
- multiple power supply disconnection
- operating temperature
- personnel
- power disconnection
- product disposal
- rack-mounting requirements
- ramp angle
- read installation instructions
- restricted access location for DC-powered routers 1, 2, 3, 4, 5
- rotating fans, compact flash replacement 1, 2
- safe rack order for multiple routers 1, 2
- telecommunications lines
- TN power system
- weight
- WinZip utility, for compact flash recovery
- wire gauge
- wiring guidelines
X