Connect a Console to the JCS 1200 Routing Engines

To access the Routing Engines from a console, you must use the serial port breakout cable provided with the chassis to connect the JCS 1200 platform. The breakout cable provides a direct serial interface to each Routing Engine in the JCS 1200 platform and contains 14 RJ-45 serial cable connectors (see Figure 9).

Figure 9: Serial Port Breakout Cable

Image dw1ce001.gif

Note: Only 12 of the 14 RJ-45 serial cable connectors are used to connect the console to the Routing Engines. Connectors 13 and 14 are reserved for future use.

To connect the console:

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the JCS 1200 Platform Hardware Guide.
  2. Connect the serial connector on the cable to the serial port connector on the alarm panel module of the JCS 1200 platform.
  3. Connect the each of the RJ-45 connectors on the cable to your console.

    Note: Some consoles require that you use a CPU adapter. If needed, connect a CPU adapter to each of the 12 RJ-45 connectors on the breakout cable. Then connect each CPU adapter to your console. For information about the CPU adapter pinouts, see the JCS 1200 Platform Hardware Guide.