Line module label
|
OCx/STMx ATM or OCx/STMx /DS3-ATM
|
I/O module label
|
OC12 STM4 APS
MULTI MODE
|
Number of I/O ports
|
|
Software release
|
-
First supported: 2.0.0 (128 MB), 5.0.0 (256 MB)
-
Final supported: Not applicable
-
The OCx/STMx ATM line module or the OCx/STMx /DS3-ATM line module
must have a minimum of 256 MB of memory to be used with JUNOSe Release 5.3.0
or a higher-numbered release.
|
Description
|
-
130 W
-
Can use either the 128-MB OCx/STMx ATM line module or the 256-MB
OCx/STMx /DS3-ATM line module.
-
Unchannelized, concatenated OC12/STM4 for ATM
|
Type |
|
Capability |
|
Software features
|
-
See OCx/STMx ATM Modules for information about the
layer 2 and layer 3 protocols and applications that this module combination
supports.
|
Model compatibility
|
-
ERX-7xx models
-
ERX-14xx models
-
ERX-310 router
|
SRP module compatibility
|
-
SRP-5G+
-
SRP-10G
-
SRP-40G
-
SRP-40G PLUS
-
SRP-SE10G
|
Module redundancy support
|
-
1:N redundancy
-
NOTE: Line module redundancy is not
supported on the ERX-310 router.
|
Cables and connectors
|
-
SC full duplex
-
Tx power:
-
min: –19 dBm
-
max: –14 dBm
-
Center wavelength: 1310 nm
-
Rx input power:
-
min: –30 dBm
-
max: –14 dBm
-
Rated for 2 km (1.2 miles) over 62.5-micron core cable with an
optical loss of 0–9 dB or 50-micron core cable with an optical loss
of 7 dB
-
See ERX Hardware Guide, Chapter 5, Cabling ERX
Routers for more information.
|
LEDs |
|
Alarms, errors, and events
|
-
See Monitoring SONET/SDH Interfaces in JUNOSe
Physical Layer Configuration Guide, Chapter 4, Configuring Unchannelized
OCx/STMx Interfaces.
|