IOA label |
ES2-S1 GE-4 IOA
|
Number of IOA ports
|
|
Software release
|
|
Description
|
-
30 W
-
Half-height module
-
See Slot Combinations for more information
on combining IOAs in a slot.
-
Uses a range of small form-factor pluggable (SFP) transceivers
to support different modes and cable lengths.
-
Uses either optical or copper SFPs.
-
The optical transceivers are 1000Base-SX, 1000Base-LX, and 1000Base-ZX
compliant.
-
The copper transceivers are 1000Base-T compliant.
|
Capability |
-
Ethernet (IEEE 802.3x)
-
1000Base-SX/LX/ZX
|
Software features
|
-
See Ethernet IOAs for information about the
layer 2 and layer 3 protocols and applications that this module combination
supports.
|
Line module compatibility
|
|
SRP module compatibility
|
|
Line module redundancy compatibility
|
-
Can be paired with an ES2 4G LM.
-
Must be installed in the same redundancy group as an ES2 4G LM
and ES2–S1 REDUND IOA combination.
|
Port redundancy support
|
|
Cables and connectors (copper SFP)
|
-
Maximum range is 100 meters on CAT5 cable.
|
Cables and connectors (multimode [SX] )
|
-
Up to four LC-style fiber-optic connectors
-
Transmit power:
-
min: –9.5 dBm
-
max: –4 dBm
-
Receive input power:
-
See the following corresponding table (SX Fiber Optic Cabling)
for cabling requirements.
-
See E320 Hardware Guide, Chapter 5, Cabling the
Router for more information.
|
Cables and connectors (single-mode [LX])
|
-
Up to four LC-style fiber-optic connectors
-
Transmit power:
-
min: –9.5 dBm
-
max: –3 dBm
-
Receive input power:
-
See the following corresponding table (LX Fiber Optic Cabling)
for cabling requirements.
-
See E320 Hardware Guide, Chapter 5, Cabling the
Router for more information.
|
Cables and connectors (single-mode [ZX]
) |
-
Up to four LC-style fiber-optic connectors
-
Transmit power:
-
Receive input power:
-
See the following corresponding table (ZX Fiber Optic Cabling)
for cabling requirements.
-
See E320 Hardware Guide, Chapter 5, Cabling the
Router for more information.
|
LEDs |
When lit, LED indicates:
-
OK (green)—Physical link is connected properly and is functioning
properly
-
FAIL (red)—Failure detected
-
Port LEDs:
-
LK (green)—Ethernet link is up
-
ACT (green)—Blinks when there is Ethernet traffic being
received
|
Alarms, errors, and events
|
-
See Monitoring Ethernet Interfaces in JUNOSe
Physical Layer Configuration Guide, Chapter 6, Configuring Ethernet Interfaces.
|