OC3/STM1 POS Single-Mode Intermediate Reach With APS/MSP Redundancy Module Combination

Line module label OCx/STMx POS
I/O module label 4XOC3
APS I/O
SINGLE MODE
Number of I/O ports
  • 4 active, 4 redundant
Software release
  • First supported: 5.1.2, 5.2.0 (APS/MSP)
  • Final supported: N/A
Description
  • 120 W
  • Unchannelized, concatenated OC3/STM1 for POS
Type
  • ASIC
Capability
  • OC3/STM1
  • HDLC framing
Software features
  • See for information about the layer 2 and layer 3 protocols and applications that this module combination supports.
Model compatibility
  • ERX-7xx models
  • ERX-14xx models
  • ERX-310 router
SRP module compatibility
  • SRP-5G+
  • SRP-10G
  • SRP-40G
  • SRP-40G PLUS
  • SRP-SE10G
Module redundancy support
  • 1:N redundancy
  • NOTE: Line module redundancy is not supported on the ERX-310 router.
Cables and connectors
  • LC full duplex
  • Tx power:
    • min: –15 dBm
    • max: –8 dBm
  • Center wavelength: 1310 nm
  • Rx input power:
    • min: –31 dBm
    • max: –8 dBm
  • Rated for 15 km (9.3 miles) of 9-micron core cable
  • See E-series Hardware Guide, Chapter 6, Cabling E-series Routers for more information.
LEDs
Alarms, errors, and events
  • See Monitoring Interfaces in JUNOSe Physical Layer Configuration Guide, Chapter 4, Configuring Unchannelized OCx/STMx Interfaces.