Redundancy IOA

IOA labelES2-S1 REDUND IOA
Number of IOA ports
  • 0
Software release
  • First supported: 7.0.1
Description
  • 10 W maximum
  • Full-height module
  • Provides redundancy for line modules
  • Inserted in slot 0 and 11 only
Capability
  • Provides switchover when a line module fails
  • Provides N+1 redundancy for line modules
  • When inserted in slot 0, provides redundancy for a failed line module in slots 1–5. When inserted in slot 11, provides redundancy for a failed line module in slots 12–16.
Software features
  • See JunosE System Basics Configuration Guide, Chapter 6, Managing Modules.
Model compatibility
  • E320 router
  • E120 router
Line module compatibility
  • ES2 4G LM
  • ES2 10G UPLINK LM
  • ES2 10G LM
  • ES2 10G ADV LM
SRP module compatibility
  • SRP-100
  • SRP-120
  • SRP-320
Line module redundancy compatibility
  • Not applicable
Port redundancy support
  • Not applicable
Cables and connectors
  • Not applicable
LEDs
  • OK (green)—Self-test passed
  • FAIL (red)—Failure detected
Alarms, errors, and events
  • See Monitoring Modules in JunosE System Basics Configuration Guide, Chapter 6, Managing Modules.