Symbols
A
- abnormal LED activity 1, 2
- access, management 1, 2
- setting up console 1, 2
- SNMP 1, 2
- Telnet setup
- accessing, fan tray
- adapters, I/O 1, 2
- agency certification 1, 2, 3, 4
- air filter 1
- airflow 1
- rack-mounted installation and
- specifications 1, 2
- alarm ports
- amperage 1, 2
- antistatic bags and containers
- assembly numbers, locating
- assigning an IP address
- auxiliary port 1, 2
B
- bays, upper and lower, right and left 1, 2, 3
- BNC connector
- booting
C
- cable management bracket
- cables
- cabling
- cabling router
- cabling SRP IOA
- Case Manager
- certification 1, 2, 3, 4
- chassis
- circulation, air
- classification, packet
- cleaning the router
- CLI (command-line interface)
- clock source input ports
- clocking problems
- command-line interface
- compliance
- components
- configuring cables 1, 2
- configuring management access
- configuring Telnet
- connecting console to the router
- connectors, pinouts
- console
- console port 1, 2
- consumption, power 1, 2
- conventions
- cooling system
- crossover cable
- current (electrical) requirements 1, 2
- customer support 1, 2
D
- damaged components, returning
- DB-9 connector 1, 2
- DC power 1, 2, 3
- detecting double-bit error
- diagnosing problems
- diagnostic LEDs
- dimensions of E120 router
- dimensions of E320 router
- dissipation, heat 1, 2
- distribution rack 1, 2
- documentation set
- double-bit errors
E
- E120 router
- assigning IP address to
- cabling
- cabling recommendations
- cleaning
- dimensions
- electrical requirements
- environmental requirements
- equipment rack requirements
- Ethernet cable
- installing
- installing modules
- lifting
- management access
- mechanical requirements
- modules
- power requirements
- powering down
- powering up
- safety guidelines
- site planning
- slot numbering
- space requirements 1, 2
- troubleshooting 1, 2
- unpacking
- views
- E320 router
- assigning IP address to
- cabling
- cabling recommendations
- cleaning
- dimensions
- electrical requirements
- environmental requirements
- equipment rack requirements
- Ethernet cable
- installing
- installing modules
- lifting
- management access
- mechanical requirements
- modules
- power requirements
- powering down
- powering up
- safety guidelines
- site planning
- slot numbering
- space requirements 1, 2
- troubleshooting 1, 2
- unpacking
- views
- EIA distribution rack
- ejectors, module
- electrical requirements 1, 2
- electronic equipment, recycling
- electrostatic discharge, precautions
- environmental requirements
- ESD grounding jack
- Ethernet link
- external timing ports
F
G
H
- halt command 1, 2
- hardware
- cable configuration 1, 2
- reclamation and recycling
- redundancy features
- repairing and replacing
- hazardous materials, reclamation and recycling
- heat dissipation 1, 2, 3
- high-availability mode
- hot-swapping fan trays
- hot-swapping modules
- humidity requirements 1, 2
- HyperTerminal
I
- I/O adapter 1, 2
- installing IOA shelf
- installing modules
- installing NVS cards 1
- installing router 1
- installing SFPs
- IOA module 1, 2
- IOA shelf 1
- IP address, assigning
J
L
M
- maintenance, system
- management
- management access 1, 2
- setting up console 1, 2
- SNMP 1, 2
- Telnet setup
- Management Information Bases
- management port
- managing modules
- manuals
- mechanical requirements for distribution rack
- MIBs (Management Information Bases)
- module reset button
- modules 1
- monitoring LEDs
- monitoring temperature
- mounting kits
- mounting posts for rack
N
- network management 1, 2
- setting up console 1, 2
- SNMP 1, 2
- Telnet setup
- network timing ports
- NMI button
- nonvolatile storage
- notice icons
- NVS cards 1
- installing 1, 2
- redundancy
- storing
O
P
- packaging, recycling
- packet classification
- packing instructions
- passwords, Telnet
- PC-CARD
- PCMCIA slot, SRP modules
- PDU 1
- pinouts, E Series router cables and connectors
- planning site for installation
- plenum
- ports
- power
- power distribution unit
- Power Distribution Unit (PDU)
- power input module, cabling
- power switches 1, 2
- powering down router
- powering up router
- preinstallation responsibilities
- preparing site for installation
- Privileged Exec command mode
- problems
- product numbers, locating
Q
R
- rack, distribution
- reclamation and recycling
- recycling Juniper Networks equipment
- redundancy 1
- regulatory requirements
- release mechanisms for SFPs
- removing components
- removing modules
- removing SFPs
- repacking components
- repairing hardware components
- replacing components
- replacing modules
- replacing NVS cards 1, 2, 3
- replacing SFPs 1, 2
- reset button
- resetting modules
- Restriction of Hazardous Substances (RoHS) Directive, recycling equipment
- Return Materials Authorization
- returning product
- RJ-45 connector 1, 2
- RMA (Return Materials Authorization)
- RoHS (Restriction of Hazardous Substances) Directive, recycling equipment
- RS-232 port 1, 2, 3, 4, 5
S
- safety
- agency certification 1, 2
- guidelines
- self-testing, modules
- serial numbers, locating
- SFM (switch fabric module) 1, 2
- SFPs (small form-factor pluggable transceivers) 1, 2
- show interface command
- show version command 1, 2, 3, 4, 5, 6, 7
- single-bit errors
- site planning
- size
- slices, fabric
- slot combinations 1, 2
- slot disable command
- slot groups 1
- slot numbering 1, 2
- small form-factor pluggable transceivers
- SNMP for management access 1, 2
- space requirements 1, 2, 3, 4
- specifications
- SRP (switch route processor) module 1, 2
- errors on
- installing
- IOA
- PCMCIA slot
- powering down
- redundancy
- removing 1, 2
- switch fabric slice 1, 2
- SRP IOA 1
- cabling 1, 2
- installing
- removing
- starting router
- static electricity, protecting against
- storing, modules and components
- support, technical See technical support
- switch fabric modules
- switch fabric slices 1, 2
- switch router processor modules
- switches, power 1, 2
- switchover, SRP modules
- synchronization, SRP modules
- system maintenance
T
- technical support 1
- Telnet connection to router
- temperature
- excessive 1, 2
- monitoring
- requirements 1, 2
- text and syntax conventions
- thermal protection mode 1, 2, 3
- timing port
- tools required
- cabling router
- installing modules
- removing components 1, 2
- unpacking router
- troubleshooting 1, 2
- booting
- cables 1, 2
- clocking
- double-bit errors
- Ethernet link
- fans 1, 2
- LED activity for
- modules 1, 2
- power failure 1, 2
- safety guidelines
U
V
W
- Waste Electrical and Electronic Equipment (WEEE) Directive. See WEEE Directive
- WEEE (Waste Electrical and Electronic Equipment) Directive, recycling equipment
- weight
- of E120 router
- of E320 router
- of rack 1, 2
Download This Guide
Console Port Setup
You can connect a console terminal (PC, Macintosh, or UNIX workstation) directly to the SRP IOA via the RS-232 terminal port. When you connect a console directly to the system, you can configure the system without an IP address.
To communicate with the system, you must have a terminal emulation program running on your PC or Macintosh. You can use any terminal emulation program, such as HyperTerminal. A UNIX workstation can use the emulator TIP.
Using HyperTerminal
If your console uses a version of Microsoft Windows (such as Windows XP or Windows NT 4.0) that supports the HyperTerminal application, you can access the system via HyperTerminal.
- Click the Start button and select Programs, Accessories, Communications, and HyperTerminal.
- In the HyperTerminal window, select HyperTerminal.
- In the Connection Description dialog box, enter a name for your router (for example, e320) in the Name field.
- Select any icon to represent your terminal emulation, and click OK.
- In the Connect To dialog box, in the Connect using field, select the appropriate COM port to use (for example, COM1), and click OK.
- In the COM1 Properties dialog box, select the following
settings:
- Bits per second: 9600
- Data bits: 8
- Parity: None
- Stop bits: 1
- Flow control: Xon/Xoff
- Click OK.
Connecting Directly to the Router
When you connect a console directly to the system, use a cable appropriate for your terminal connector. The cable must have a female DB-9 connector to attach to the RS-232 port on the system.
The console port is considered a data terminal equipment interface (DTE). Direct connection to a terminal or PC (which also have DTE interfaces) requires a crossover cable.
To connect a console directly to the system:
- Connect the female DB-9 connector to the RS-232 port on
the router's SRP IOA. See Figure 28.
Figure 28: Router Management Ports
- Connect the crossover adapter connector to your PC's serial port.
- Power up the system.
When you power up the system, the CLI appears on your console's screen. The system is now in User Exec mode, and you can begin configuration. For more information on using the CLI and configuring the system, see the JunosE System Basics Configuration Guide.
Note: Direct access through the RS-232 serial port enables you to monitor the system while it boots.
Assigning an IP Address
When your console is ready to communicate with the system, power up the system. (See Powering Up the Router.) Then set an IP address for the system. The system powers up in User Exec mode. To assign an IP address:
- Enter the enable command at
the User Exec prompt.host1>enablehost1#
The system is now in Privileged Exec mode.
- Set an IP address on the Ethernet interface:
- Specify the identifier of the FastEthernet interface in the format: slot/adapter/port.
- Use an IP address valid for the system.host1#configure terminalEnter configuration commands, one per line. End with CNTL/Z. host1(config)#interface FastEthernet 6/0/0host1(config-if)#ip address 10.10.7.3 255.255.255.0
- Continue to configure the system's parameters as needed.
After you have assigned an IP address to the system, you can communicate remotely by running Telnet over an Ethernet network. See Telnet Setup.