Weight | |
Chassis only | 88 lb (39.9 kg) |
Chassis fully configured | Approximately 215 lb (97.5 kg) |
Dimensions | |
With cable management bracket and bezels | 24.5 (H) x 19 (W) x 28 (D) inches; 62.23 x 48.26 x 71.12 cm |
Chassis only | 24.5 (H) x 19 (W) x 25 (D) inches; 62.23 x 48.26 x 63.5 cm |
Environmental Requirements | NEBS GR-63-CORE compliant |
Ambient operating temperature | - Long term: 41° to 104° F (5° to 40° C)
- Short term: 23° to 122° F (–5° ˚
to 50° C)
|
Ambient operating humidity | - Long term: 5% to 85% (noncondensing)
- Short term: 5% to 95% (noncondensing)
|
Ambient storage temperature | –40° ˚ to 158° F (–40° ˚ to
70° C), 95% relative humidity |
Ambient storage humidity | 5% to 95% (noncondensing) |
Heat Dissipation | 3840 W, 13106 BTU/hour maximum |
DC Input | |
Voltage | –40 to –72 VDC NOTE: If the voltage rises above
–40 VDC, the system powers off. The system does not power on
again until the input voltage reaches –43 +/– 0.5 VDC. |
Current | 80 A @ –48 VDC |
Power | 3840 W maximum |
Redundancy (input power) | 2 independent line feeds |
Space Requirements | - 3 feet (90 cm) behind router or rack
- Do not block air vents on front, sides, top, or back of
the router
|
Airflow | - Air intake occurs in the front and left and right sides
of the router.
- Air is exhausted out of the top of the router.
- Exhaust air from components installed below the router
is directed by an integral plenum out the back. See Figure 34.
|
NEBS Certification Level
3 | - SR-3580 (FD-15): Network Equipment Building System (NEBS)
Criteria Levels, Issue 1, November 1995
- GR-63–CORE: Network Equipment Building System (NEBS)
Requirements: Physical Protection, Issue 2, April 2002
- GR-1089 (LSSGR, FD-15): Electromagnetic Compatibility
and Electrical Safety - Generic Criteria for Network Telecommunications
Equipment, Issue 2, Revision 1, February 1999
|
Safety Agency Certification | - AS/NZS 60950:2000 Safety of Information Technology Equipment
- CAN/CSA-C22.2, No. 60950-1–03, First Edition, Information
Technology Equipment - Safety - Part 1: General Requirements
- EN60825-1, Safety of Laser Products - Part 1: Equipment
Class, Requirements, and User's Guide (2001)
- EN 60950-1:2001, First Edition, Information Technology
Equipment - Safety - Part 1: General Requirements
- IEC 60950-1(2001-10) Ed. 1.0 Information Technology Equipment
- Safety - Part 1: General Requirements
- Low Voltage Directive (73/23/EEC)
- UL 60950-1, First Edition, Information Technology Equipment
- Safety - Part 1: General Requirements
|
Electromagnetic Emissions
Agency Certification | - AS/NZS 3548:1995 (CISPR 22 Class A)
- EMC Directive (89/336/EEC)
- EN55022 Class A (CISPR-22 Class A)
- EN55024, Annex C for WAN Equipment Performance Criteria
A, B, and C
- ETSI 300-386, Telecommunication Network Equipment; ElectroMagnetic
Compatibility (EMC) requirements
- FCC Part 15 Class A
- IECS-03 Issue 3 Class A
- VCCI (Voluntary Control Council for Interference by Information
Technology Equipment)
|