E120 Broadband Services Router Specifications

Table 14: E120 Router Specifications

Category

Specification

Weight 

Chassis only

51 lb (23.1kg)

Chassis fully configured

Approximately 107 lb (48.5 kg)

Dimensions 

Chassis only

11.25 (H) x 17.45 (W) x 25.10 (D) inches; 28.57 x 44.32 x 63.75 cm

Environmental Requirements

Pending

Ambient operating temperature

  • Long term: 41° to 104° F (5° to 40° C)
  • Short term: 23° to 122° F (–5° ˚ to 50° C)

Ambient operating humidity

  • Long term: 5% to 85% (noncondensing)
  • Short term: 5% to 95% (noncondensing)

Ambient storage temperature

–40° ˚ to 158° F (–40° ˚ to 70° C), 95% relative humidity

Ambient storage humidity

5% to 95% (noncondensing)

Heat Dissipation

1920 W, 6553 BTU/hour maximum

DC Input 

Voltage

–40 to –72 VDC

NOTE: If the voltage rises above –40 VDC, the system powers off. The system does not power on again until the input voltage reaches –43 +/– 0.5 VDC.

Current

40 A @ –48 VDC

Power

1920 W maximum

Redundancy (input power)

2 independent line feeds

Space Requirements
  • 3 feet (90 cm) behind router or rack
  • Do not block air vents on sides of the router
  • Do not place equipment that exhausts hot air to left on the right of the router.
Airflow
  • Air intake occurs from the right side of the router.
  • Air is exhausted out of the left side of the router.
NEBS Certification Level 3

Pending

Safety Agency Certification
  • AS/NZS 60950:2000 Safety of Information Technology Equipment
  • CAN/CSA-C22.2, No. 60950-1–03, First Edition, Information Technology Equipment - Safety - Part 1: General Requirements
  • EN60825-1, Safety of Laser Products - Part 1: Equipment Class, Requirements, and User's Guide (2001)
  • EN 60950-1:2001, First Edition, Information Technology Equipment - Safety - Part 1: General Requirements
  • IEC 60950-1(2001-10) Ed. 1.0 Information Technology Equipment - Safety - Part 1: General Requirements
  • Low Voltage Directive (73/23/EEC)
  • UL 60950-1, First Edition, Information Technology Equipment - Safety - Part 1: General Requirements
Electromagnetic Emissions Agency Certification

  • AS/NZS CISPR 22:2004
  • EMC Directive (89/336/EEC)
  • EN 300 132–2 (Narrowband and Wideband)
  • EN55022 Class A (CISPR-22 Class A)
  • EN55024, Annex C for WAN Equipment Performance Criteria A, B, and C
  • EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6
  • ETSI 300-386, Telecommunication Network Equipment; ElectroMagnetic Compatibility (EMC) requirements
  • FCC Part 15 Class A
  • IECS-03 Issue 3 Class A
  • VCCI (Voluntary Control Council for Interference by Information Technology Equipment)