[Contents] [Prev] [Next] [Index] [Report an Error]


SRP I/O Module

The SRP I/O module provides two management ports. You can connect a console directly to the RS-232 serial port using a shielded straight-through cable with a female DB-9 connector on one end and a male DB-25 with a crossover adapter on the DB-25 end. This port is called the serial port, the RS-232 port, or the console serial port. Figure C-1 shows the location of the serial port and the sequence of the pins in the RS-232 connector.


Figure C-1 SRP I/O module serial port

Table C-2 lists the pinout for the serial cable's RS-232 connector.

Table C-1 SRP I/O module - RS-232 serial connector pinout 
Pin
Signal
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RNG

Once you have configured an IP address on the system, you can connect a console running Telnet to the 10/100Base-T Ethernet port on the SRP I/O module. The system ships with a straight-through cable having a male RJ-45 Ethernet connector on each end. Figure C-2 shows the location of the Ethernet port and the sequence of the pins in the RJ-45 connector.


Figure C-2 SRP I/O module Ethernet port

Table C-2 lists the pinout for the Ethernet cable's RJ-45 connector.

Table C-2 SRP I/O module - RJ-45 connector pinout 
Pin
Signal
1
TX +
2
TX -
3
RX +
4
n/c
5
n/c
6
RX -
7
n/c
8
n/c

To facilitate connecting the system to a terminal, the system is shipped with one of each of the following cable adapters:

Table C-3 lists the pinout for the crossover adapter.

Table C-3 DB-9 - RJ-45 crossover adapter pinout 
DB-9 Pin
Signal
RJ-45 Pin
1
DCD
1
2
RXD
3
3
TXD
2
4
DTR
6
5
GND
5
6
DSR
4
7
RTS
8
8
CTS
7
9
RNG
n/c

Table C-4 lists the pinout for the straight-through adapter.

Table C-4 DB-9 - RJ-45 straight-through adapter pinout 
DB-9 Pin
RS-232 Signal Name
RJ-45 Pin
Ethernet Signal Name
1
DCD
1
TX +
2
RXD
2
TX -
3
TXD
3
RX +
4
DTR
4
n/c
5
GND (signal)
5
n/c
6
DSR
6
RX -
7
RTS
7
n/c
8
CTS
8
n/c
9
RNG
n/c
none