C2000 Model Specifications
Table 10: C2000 Model Specifications
Category | Specification |
---|
Weight | 33 lb (15 kg) |
Dimensions | 3.5 (H) x 16.7 (W) x 16.2 (D) inches 8.89 (H)
x 42.42 (W) x 41.15 (D) cm |
Environmental Requirements | |
Temperature | - Operating: 50° to 104° F (10° to 40° C)
- Storage: –40° to 158° F (–40°
˚ to 70° C)
|
Relative humidity | - Operating: 8% to 90% (noncondensing)
- Storage: 5% to 95% (noncondensing)
|
Heat Dissipation | 500 W, 1706 BTU/hour maximum |
AC Input | |
Power required | - 90-132 VAC (115V Nominal), 47–63 Hz
- 180–264 VAC (230V Nominal), 47–63 Hz
|
Power | 500 W |
Efficiency | 65% minimum at full load |
DC Input | |
Voltage | -48 to -60 VDC |
Current | -48 V nominal |
Power | 500 W |
Efficiency | 70% minimum at full load |
Space Requirements | - 3 feet (90 cm) behind system or rack.
- Do not block air vents on front or back of the system.
|
Safety Agency Certification | - CAN/CSA-C22.2 No. 60950-1-03
- EN 60950-1:2001+A11
- EN 60825-1:1994+A1+A2
- Low Voltage Directive 73/23/EEC
- UL 60950-1:2003
|
Airflow | - Air intake occurs in the front of the system.
- Air is exhausted out of the rear of the system.
|
Electromagnetic Emissions
Agency Certification | - AZ/NZS CISPR 22:2002
- EMC Directive (89/336/EEC)
- EN 300 386 V1.3.3:2005
- EN 300 386 V1.3.3:2005
- EN 55022:1998+A1 (2000)+A2(2003) Class A
- EN 55024: 1998+A1: 2001+A2: 2003
- EN 61000-3-2:2001
- EN 61000-3-3:1995
- FCC Part 15 Subpart B
- VCCI (Voluntary Control Council for Interference by Information
Technology Equipment)
|