Viewing IPMI Chassis Information

You can view IPMI chassis information for the controller you are currently logged in to and for a remote controller. You must be logged on as a root user.

To display the chassis information on the local controller using IPMI:

  1. Log in as root user.
    SRC-PE Release 3.1 [R.3.1.0-12]login: root
  2. Enter the password.
    Password: password

    You are now logged in as root user.

  3. Access the CLI.
    [root@host ~]# cli--- SRC CLI 3.1 build CLI.R.3.1.0.012 (c) 2005-2008 Juniper Networks Inc. root@host>
  4. Enter the show ipmi chassis command.

    For example:


    root@host>show ipmi chassis
    System Power         : on
    Power Overload       : false
    Power Interlock      : inactive
    Main Power Fault     : false
    Power Control Fault  : false
    Power Restore Policy : always-off
    Last Power Event     : 
    Chassis Intrusion    : inactive
    Front-Panel Lockout  : inactive
    Drive Fault          : false
    Cooling/Fan Fault    : false
    System Power         : on
    Power Overload       : false
    Power Interlock      : inactive
    Main Power Fault     : false
    Power Control Fault  : false
    Power Restore Policy : always-off
    Last Power Event     : 
    Chassis Intrusion    : inactive
    Front-Panel Lockout  : inactive
    Drive Fault          : false
    Cooling/Fan Fault    : false

To display the IPMI chassis information on a remote controller:

  1. Log in as root user.
  2. Enter the show ipmi host chassis command.
    user@host>show ipmi host host user user chassis
    • host—IP address of remote host IPMI interface
    • user—IPMI username configured in the remote host

    For example:

    root@host>show ipmi host 10.10.10.30 user johndoe chassis