C4000 Model Specifications

Table 7: C4000 Model Specifications

Category

Specification

Weight

48 lb (22 kg)

Dimensions

3.5 (H) x 16.7 (W) x 24 (D) inches
8.89 (H) x 42.42 (W) x 60.96 (D) cm

Environmental Requirements 

Temperature

  • Operating: 50° to 104° F (10° to 40° C)
  • Storage: –40° to 158° F (–40° ˚ to 70° C)

Relative humidity

  • Operating: 8% to 90% (noncondensing)
  • Storage: 5% to 95% (noncondensing)

Ambient storage temperature

–40° ˚ to 158° F (–40° ˚ to 70° C), 95% relative humidity

Ambient storage humidity

5% to 95% (noncondensing)

Heat Dissipation

700 W, 2389 BTU/hour maximum

AC Input 

Power required

90-264 VAC, 47–63 Hz

Power

700 W

Efficiency

80% minimum at full load

Space Requirements
  • 3 feet (90 cm) behind system or rack.
  • Do not block air vents on or back of the system.
Airflow
  • Air intake occurs in the front of the system.
  • Air is exhausted out of the rear of the system.
Safety Agency Certification
  • CAN/CSA-C22.2 No. 60950-1-03
  • EN 60950-1:2001+A11
  • EN 60825-1:1994+A1+A2
  • Low Voltage Directive 73/23/EEC
  • UL 60950-1:2003
Electromagnetic Emissions Agency Certification
  • AZ/NZS CISPR 22:2002
  • EMC Directive (89/336/EEC)
  • EN 55022:1998+A1 (2000)+A2(2003) Class A
  • EN 55024: 1998+A1: 2001+A2: 2003
  • EN 61000-3-2:2001
  • EN 61000-3-3:1995
  • FCC Part 15 Subpart B
  • VCCI (Voluntary Control Council for Interference by Information Technology Equipment)