Defining Alarm Thresholds for System Temperature Sensors

To configure SNMP chassis alarm thresholds for system temperature sensors:

  1. Set the editing level for the CLI to expert.
    user@host> set cli level expert
  2. From configuration mode, access the configuration statement that defines the thresholds for system temperature sensors.
    [edit]user@host# edit snmp monitor chassis-alarm system-temperature
  3. (Optional) Specify the upper threshold for the minor alarm. For example:
    [edit snmp monitor chassis-alarm system-temperature]user@host# set minor 76
  4. (Optional) Specify the upper threshold for the major alarm. For example:
    [edit snmp monitor chassis-alarm system-temperature]user@host# set major 78
  5. (Optional) Specify the upper threshold for the critical alarm. For example:
    [edit snmp monitor chassis-alarm system-temperature]user@host# set critical 80