    Configuring a RADIUS Packet Template (SRC CLI)

    You can define RADIUS packets for flexible RADIUS accounting and authentication plug-ins in two ways.

    • Define attributes in a template, and then apply the template to flexible RADIUS accounting and authentication plug-ins.
    • Define attributes in the packet definition configuration of a flexible plug-in instance. These definitions override definitions in packet templates.

    Use the following configuration statements to configure a RADIUS packet template:

    shared sae configuration radius-packet-template name ...shared sae configuration radius-packet-template name radius-attributes name ...
    shared sae configuration radius-packet-template name radius-attributes name attributes name { value ; }
    shared sae configuration radius-packet-template name radius-attributes name attributes-with-type name
    shared sae configuration radius-packet-template name radius-attributes name attributes-with-type name (address | hex | integer | string | text) {value; }
    shared sae configuration plug-ins name name flex-radius-accounting radius-packet-definition name ...
    shared sae configuration plug-ins name name flex-radius-accounting radius-packet-definition name attributes name { value ; }
    shared sae configuration plug-ins name name flex-radius-accounting radius-packet-definition name attributes-with-type...
    shared sae configuration plug-ins name name flex-radius-accounting radius-packet-definition name attributes name attributes-with-type name { value ; }
    shared sae configuration plug-ins name name flex-radius-authentication radius-packet-definition name ...
    shared sae configuration plug-ins name name flex-radius-authentication radius-packet-definition name attributes name { value ; }
    shared sae configuration plug-ins name name flex-radius-authentication radius-packet-definition name attributes-with-type...
    shared sae configuration plug-ins name name flex-radius-authentication radius-packet-definition name attributes name attributes-with-type name { value ; }

    To configure a template:

    1. From configuration mode, access the RADIUS packet template configuration. In this sample procedure, the stdAcct template is configured in the west-region service activation engine (SAE) group.
      user@host# edit shared sae group west-region configuration radius-packet-template stdAcct
    2. Create an attribute instance using the names in Flexible RADIUS Plug-Ins Overview, and enter the configuration for the RADIUS attribute instance.
      [edit shared sae group west-region configuration radius-packet-template stdAcct] user@host# edit radius-attributes name
    3. Add RADIUS attribute definitions to the attribute instance. Repeat this step for each attribute.
      [edit shared sae group west-region configuration radius-packet-template stdAcct radius-attributes svcstop]user@host# set attributes name value

      For example:

      [edit shared sae group west-region configuration radius-packet-template stdAcct radius-attributes svcstop]user@host# set attributes Acct-Session-ID sessionId
    4. (Optional) Verify the configuration of your attribute instance.
      [edit shared sae group west-region configuration radius-packet-template stdAcct radius-attributes svcstop]
      user@host# show 
      attributes {
       Acct-Input-Octets lowWord(inOctets);
        Acct-Output-Octets lowWord(outOctets);
        Acct-Input-Packets lowWord(inPackets);
        Acct-Output-Packets lowWord(outPackets);
        Acct-Input-Gigawords highWord(inOctets);
        Acct-Output-Gigawords highWord(outOctets);
      }
    5. (Optional) Verify the configuration of the RADIUS packet template.
      [edit shared sae group west-region configuration radius-packet-template stdAcct radius-attributes svcstop]
      user@host# up 
      [edit shared sae group west-region configuration radius-packet-template stdAcct]
      user@host# show 
      radius-attributes svcstop {
        attributes {
          Acct-Input-Octets lowWord(inOctets);
          Acct-Output-Octets lowWord(outOctets);
          Acct-Input-Packets lowWord(inPackets);
          Acct-Output-Packets lowWord(outPackets);
          Acct-Input-Gigawords highWord(inOctets);
          Acct-Output-Gigawords highWord(outOctets);
        }
      }
      radius-attributes stop {
        attributes {
          Acct-Session-Time sessionTime;
          Acct-Terminate-Cause terminateCause;
        }
      }
      radius-attributes svcacct {
        attributes {
          Chargeable-User-Identity userSessionProperties.CUI;
          Class radiusClass;
        }
      }
      radius-attributes acct {
        attributes {
          Acct-Session-Id sessionId;
          NAS-Identifier localNasId;
          NAS-IP-Address localNasIp;
          Event-Time eventTime;
        }
      }
      radius-attributes startstop {
        attributes {
          Acct-Multi-Session-Id ifSessionId;
          NAS-Port-Id "\"%s %s\" %(routerName, portId or interfaceName)";
          NAS-Port "nasPort or None";
        }
      }

      Note: You must configure any one of the following values to set the Chargeable-User-Identity attribute value in the accounting-request packet.

      • userSessionProperties.CUI
      • getUserSessionProperties().CUI
      • getUserSessionProperties().get(“CUI”)
      • getUserSessionProperties()[CUI]
      • userSessionProperties().CUI