Defining Alarm Thresholds for Fan Speed Sensors
To configure SNMP chassis alarm thresholds for fan speed sensors:
Set the editing level for the CLI to expert.
user@host> set cli level expertFrom configuration mode, access the configuration statement that configures the chassis alarm thresholds for fan speed sensors.
[edit]user@host# edit snmp monitor chassis-alarm fan-speed(Optional) Specify the lower threshold for the minor alarm in revolutions per minute. For example:
[edit snmp monitor chassis-alarm fan-speed]user@host# set minor 540(Optional) Specify the lower threshold for the major alarm in revolutions per minute. For example:
[edit snmp monitor chassis-alarm fan-speed]user@host# set major 405(Optional) Specify the lower threshold for the critical alarm in revolutions per minute. For example:
[edit snmp monitor chassis-alarm fan-speed]user@host# set critical 270