Configuring Event Notification for External Subscriber Monitor (SRC CLI)
Use the following configuration statements to configure External Subscriber Monitor as a RADIUS accounting server:
To configure event notification:
From configuration mode, access the configuration statement that configures the event notification.
user@host# edit slot 0 external-subscriber-monitor event-notification(Optional. Available at the Advanced editing level.) Specify the maximum number of concurrent threads in a pool for event handlers. The value range is 1 through 2,147,483,647 seconds. By default, the value is set to 8.
[edit slot 0 external-subscriber-monitor event-notificationuser@host# set event-threads event-threads(Optional. Available at the Advanced editing level.) Specify the time to keep an event handler alive for reuse. The value range is 1 through 2,147,483,647 seconds. By default, the value is set to 300.
[edit slot 0 external-subscriber-monitor event-notificationuser@host# set event-thread-idle timeout event-thread-idle-timeout(Optional. Available at the Advanced editing level.) Specify the maximum retry time before an event is discarded. The value range is 1 through 2,147,483,647 seconds. By default, the value is set to 300.
[edit slot 0 external-subscriber-monitor event-notification]user@host# set event-retry-timeout event-retry-timeout.(Optional. Available at the Advanced editing level.) Specify the time to wait before the server retries failed events. The value range is 1 through 2,147,483,647 seconds. By default, the value is set to 30.
[edit slot 0 external-subscriber-monitor event-notification]user@host# set event-retry-interval event-retry-interval(Optional.) Specify the keepalive time for a RADIUS subscriber or service. The value range is -2,147,483,648 through 2,147,483,647 seconds. By default, the value is set to 1800.
[edit slot 0 external-subscriber-monitor event-notification]user@host# set session-timeout session-timeout