Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Powering a Remote Controller On and Off Using IPMI (SRC CLI)
You can power on or off, and reset a remote C Series Controller.
To execute a power command on a remote controller using IPMI:
- Log in to the C Series Controller.
- Enter the request ipmi host user power command.
Note: The request ipmi host user power command is not supported, if the SRC software is deployed as a virtual machine.
user@host>request ipmi host host user user power (on | off | soft-off | reset| cycle)where:
- host—IP address of the remote IPMI module.
- user—IPMI user account name.
For example:
user@host>request ipmi host 10.10.10.30 user johndoe power reset - When prompted, enter the IPMI password configured on the remote system.