To configure SNMP chassis alarm thresholds for system temperature sensors:
- Set the editing level for the CLI to expert.user@host> set cli level expert
- From configuration mode, access the configuration statement
that defines the thresholds for system temperature sensors. [edit]user@host# edit snmp monitor chassis-alarm system-temperature
- (Optional) Specify the upper threshold for the minor alarm.
For example:[edit snmp monitor chassis-alarm system-temperature]user@host# set minor 76
- (Optional) Specify the upper threshold for the major alarm.
For example:[edit snmp monitor chassis-alarm system-temperature]user@host# set major 78
- (Optional) Specify the upper threshold for the critical
alarm. For example:[edit snmp monitor chassis-alarm system-temperature]user@host# set critical 80