Defining an Alarm for an SNMP Monitor That Compares Values Against Thresholds (SRC CLI)
You can configure a monitor to compare a sample value for a MIB object to a threshold encountered as the value rises and a threshold encountered as the value falls.
![]() | Note: Configure only one monitor test at a time. |
Before you define an alarm type, configure the associated SNMP alarm.
See Configuring an SNMP Alarm on a C Series Controller (SRC CLI).
To configure an alarm for a monitor that compares a sample value to an upper threshold value and a lower threshold value:
- Define the upper threshold against which to compare a
rising sample value. For example:[edit snmp monitor alarm thresholds threshold-test]user@host# set rising-threshold 2
- Define the lower threshold against which to compare a
falling sample value. For example:[edit snmp monitor alarm threshold-alarm]user@host# set falling-threshold 1
Related Documentation
- C Series
- Defining an Alarm for an SNMP Monitor That Compares Object Values (SRC CLI)
- Defining an Alarm to Monitor the Status of an Object (SRC CLI)
- Configuring an SNMP Alarm on a C Series Controller (SRC CLI)
- Configuration Statements for Customized SRC SNMP Monitors
- SNMP Monitoring on C Series Controllers