Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Adding Objects for CMTS Devices (SRC CLI)
To manage CMTS devices, the SAE creates and manages pseudointerfaces that it associates with a virtual router object. Each CMTS device in the SRC network must appear in the configuration as a router object, and it must be associated with a virtual router object called default. The router and virtual router are not actually configured on the CMTS device; the router and virtual router provide a way for the SAE to manage the CMTS device by using the SAE’s embedded policy server.
Use the following configuration statements to add a router object:
shared network device name {description description ;
management-address management-address ;
device-type (junose | junos | pcmm | proxy);
qos-profile [ qos-profile ...];}
management-address management-address ;
device-type (junose | junos | pcmm | proxy);
qos-profile [ qos-profile ...];}
To add a router:
- From configuration mode, access the configuration statements
that configure network devices. In this sample procedure, pcmm_dtr
is the name of the object. user@host# edit shared network device pcmm_dtr
- (Optional) Add a description for the CMTS device. [edit shared network device pcmm_dtr] user@host# set description description
- Add the IP address of the CMTS device. [edit shared network device pcmm_dtr] user@host# set management-address management-address
- (Optional) Specify the type of device that you are adding. [edit shared network device pcmm_dtr] user@host# set device-type pcmm
- (Optional) Verify your configuration.
[edit shared network device pcmm_dtr] user@host# show description "CMTS device"; management-address 192.168.3.5; device-type pcmm; interface-classifier { rule rule-0 { script #; } }