Use the following configuration statements to configure properties for the Event Notification API:

shared sae configuration external-interface-features name EventAPI {retry-time retry-time ;
retry-limit retry-limit ;
threads threads ;
}

To configure properties for the Event Notification API:

  1. From configuration mode, access the configuration statements for the Event Notification API. In this sample procedure, west-region is the name of the SAE group, and event_api is the name of the Event API configuration.
    user@host# edit shared sae group west-region configuration external-interface-features event_api EventAPI
  2. Specify the amount of time between attempts to send events that could not be delivered.
    [edit shared sae group west-region configuration external-interface-features event_api EventAPI] user@host# set retry-time retry-time
  3. Specify the number of times an event fails to be delivered before the event is discarded.
    [edit shared sae group west-region configuration external-interface-features event_api EventAPI] user@host# set retry-limit retry-limit
  4. Specify the number of threads allocated to process events.
    [edit shared sae group west-region configuration external-interface-features event_api EventAPI] user@host# set threads threads
  5. (Optional) Verify the configuration of the Event Notification API properties.
    [edit shared sae group west-region configuration external-interface-features event_api EventAPI] 
    user@host# show 
    EventAPI { 
     retry-time 300;
     retry-limit 5;
      threads 5;
    }

Related Documentation

  • Using the SAE in a PCMM Environment
  • Configuring SAE Properties for the Event Notification API (C-Web Interface)
  • Initially Configuring the SAE
  • Configuring the SAE to Manage PCMM Devices (SRC CLI)