Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation  Back up to About Overview 
  
[+] Expand All
[-] Collapse All

Defining Alarm Thresholds for Voltage Sensors

You can configure alarm thresholds for these voltage sensors:

  • 1.8V
  • 3.3V
  • 5V
  • 12V
  • –12V

To configure SNMP chassis alarm thresholds for voltage sensors:

  1. Set the editing level for the CLI to expert.
    user@host> set cli level expert
  2. From configuration mode, access the configuration statement that defines the thresholds for voltage sensors.
    [edit]user@host# edit snmp monitor chassis-alarm voltage-sensor

    For example:

    [edit]user@host# edit snmp monitor chassis-alarm voltage-1.8v
    [edit]user@host# edit snmp monitor chassis-alarm voltage-3.3v
    [edit]user@host# edit snmp monitor chassis-alarm voltage-5v
    [edit]user@host# edit snmp monitor chassis-alarm voltage-12v
    [edit]user@host# edit snmp monitor chassis-alarm voltage-negative12v

    Note: The voltage-negative12v option is not available on the C3000 and C5000 Controllers.

  3. (Optional) Specify the lower threshold for the minor alarm. For example:
    [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set below-minor 1644
  4. (Optional) Specify the lower threshold for the major alarm. For example:
    [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set below-major 1632
  5. (Optional) Specify the lower threshold for the critical alarm. For example:
    [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set below-critical 1620
  6. (Optional) Specify the upper threshold for the minor alarm. For example:
    [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set over-minor 2028
  7. (Optional) Specify the upper threshold for the major alarm. For example:
    [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set over-major 2040
  8. (Optional) Specify the upper threshold for the critical alarm. For example:
    [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set over-critical 2052

Related Documentation

Modified: 2017-08-02