Defining Alarm Thresholds for Voltage Sensors
You can configure alarm thresholds for these voltage sensors:
- 1.8V
- 3.3V
- 5V
- 12V
- –12V
To configure SNMP chassis alarm thresholds for voltage sensors:
- Set the editing level for the CLI to expert.user@host> set cli level expert
- From configuration mode, access the configuration statement
that defines the thresholds for voltage sensors. [edit]user@host# edit snmp monitor chassis-alarm voltage-sensor
For example:
[edit]user@host# edit snmp monitor chassis-alarm voltage-1.8v[edit]user@host# edit snmp monitor chassis-alarm voltage-3.3v[edit]user@host# edit snmp monitor chassis-alarm voltage-5v[edit]user@host# edit snmp monitor chassis-alarm voltage-12v[edit]user@host# edit snmp monitor chassis-alarm voltage-negative12vNote: The voltage-negative12v option is not available on the C3000 and C5000 Controllers.
- (Optional) Specify the lower threshold for the minor alarm.
For example:[edit snmp monitor chassis-alarm voltage-1.8v]user@host# set below-minor 1644
- (Optional) Specify the lower threshold for the major alarm.
For example:[edit snmp monitor chassis-alarm voltage-1.8v]user@host# set below-major 1632
- (Optional) Specify the lower threshold for the critical
alarm. For example:[edit snmp monitor chassis-alarm voltage-1.8v]user@host# set below-critical 1620
- (Optional) Specify the upper threshold for the minor alarm.
For example:[edit snmp monitor chassis-alarm voltage-1.8v]user@host# set over-minor 2028
- (Optional) Specify the upper threshold for the major alarm.
For example:[edit snmp monitor chassis-alarm voltage-1.8v]user@host# set over-major 2040
- (Optional) Specify the upper threshold for the critical
alarm. For example:[edit snmp monitor chassis-alarm voltage-1.8v]user@host# set over-critical 2052