    Defining Alarm Thresholds for Voltage Sensors

    You can configure alarm thresholds for these voltage sensors:

    • 1.8V
    • 3.3V
    • 5V
    • 12V
    • –12V

    To configure SNMP chassis alarm thresholds for voltage sensors:

    1. Set the editing level for the CLI to expert.
      user@host> set cli level expert
    2. From configuration mode, access the configuration statement that defines the thresholds for voltage sensors.
      [edit]user@host# edit snmp monitor chassis-alarm voltage-sensor

      For example:

      [edit]user@host# edit snmp monitor chassis-alarm voltage-1.8v
      [edit]user@host# edit snmp monitor chassis-alarm voltage-3.3v
      [edit]user@host# edit snmp monitor chassis-alarm voltage-5v
      [edit]user@host# edit snmp monitor chassis-alarm voltage-12v
      [edit]user@host# edit snmp monitor chassis-alarm voltage-negative12v

      Note: The voltage-negative12v option is not available on the C3000 and C5000 Controllers.

    3. (Optional) Specify the lower threshold for the minor alarm. For example:
      [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set below-minor 1644
    4. (Optional) Specify the lower threshold for the major alarm. For example:
      [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set below-major 1632
    5. (Optional) Specify the lower threshold for the critical alarm. For example:
      [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set below-critical 1620
    6. (Optional) Specify the upper threshold for the minor alarm. For example:
      [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set over-minor 2028
    7. (Optional) Specify the upper threshold for the major alarm. For example:
      [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set over-major 2040
    8. (Optional) Specify the upper threshold for the critical alarm. For example:
      [edit snmp monitor chassis-alarm voltage-1.8v]user@host# set over-critical 2052

    Modified: 2016-04-07