Installing Signalware Service Pack 6V or 6.3

 

Installing Service Pack 6V or 6.3 builds on the example of a default Signalware 9 installation earlier in this chapter.

This patch installation example uses the same user (siguser) and user group (users) information and assumes that you have performed the base installation and configuration procedures documented earlier in this chapter.

Note

Ensure that before you upgrade to SP6.V or SP6.3, you have SP6.0 installed in the system.

Installing the Patch Package

Installing the Patch Package

To add Service Pack 6V or 6.3 to a Signalware 9 SP6.0 installation:

  1. Log in as root.

  2. If you have not done so already, download and unpack the Signalware 9 Service Pack 6V or 6.3 file.

  3. Copy the Signalware Service Pack 6V or 6.3 package file from its location in your download directory or from a Signalware CD to a temporary working directory. (/tmp/omni/6V is used in the example in this section).

  4. If Signalware is running, shut it down.

  5. Stop the RADIUS process.

  6. Start the Signalware installation.

    Execute:

    swsetup

    The script prompts you for a user identifier.

  7. Enter the unique user account that you created in the initial installation: siguser.

    The Signalware Main Menu is displayed.

  8. Enter 1 to install the patch.

    The Install/Configure menu is displayed.

  9. Enter 4 to select the Signalware installation that requires the patch.

    The Instance Selection screen is displayed.

    If you are working on a system with the default configuration, only one installation is listed.

  10. Enter 1 to select the location of the Signalware 9 installation.

    The Upgrade Instance screen is displayed.

  11. Enter 1 to install the package.

    The Package Directory screen is displayed.

  12. Enter the path to the patch package file. The example in Step 10 shows /tmp/omni/6V as the source location.

    If the install prompts for either a Quick Install or Advanced Install, choose the Quick Install option.

    The Upgrade Instance screen is displayed after the patch is applied.

  13. Enter 2 to configure the platform on the installed instance.

    The Configure Platform screen is displayed.

  14. Enter 0 to accept the installation directory that you entered earlier.

    The script checks for any platform configuration that you created previously and displays if it exists.

  15. Enter yes to use the existing platform configuration.

    For detailed instructions about how to configure a new platform, see Configuring the Platform.

  16. Enter yes to have the existing platform configuration take effect.

  17. Press Enter to continue with the remaining steps of the installation.

    The Upgrade Instance screen is displayed.

  18. Enter 3 to install drivers and configure the Signalware daemons.

    The Commission Instance screen is displayed.

  19. Enter 0 to accept the install directory that you entered earlier.

  20. Press Enter to continue with the remaining steps of the installation.

    The Upgrade Instance screen is displayed.

  21. Enter 4 to configure the node.

    The Enter SHM screen is displayed.

  22. Enter the shared memory value based on the user ID of the siguser user account that you created earlier (see Beginning the Installation).

    You can determine the user ID by entering the cat /etc/passwd command in a new window.

    The Signalware User screen is displayed.

  23. Enter the user account as siguser for running the Signalware.

    The Configure Nodes screen is displayed.

  24. Enter 0 to accept the values.

    The script checks for any node configuration that you created previously and prompts you to specify whether you want to use the existing node configuration.

  25. Enter Y to use the existing node configuration.

    For detailed instructions about how to configure a new node, see Configuring Nodes.

  26. Press Enter to continue with the remaining steps of the installation.

    The Upgrade Instance screen is displayed.

  27. Enter 5 to start the Signalware.

    After the Signalware is successfully started, the following prompt appears:

  28. Press Enter to continue with the remaining steps of the installation.

    The Upgrade Instance screen is displayed.

  29. Enter 6 to exit.

    The Install/Configure menu is displayed.

  30. Press F11.

    The Signalware Main Menu is displayed.

  31. Press F11.

    The Product Menu is displayed.

  32. Enter 7 to exit from the Product Menu.

  33. Enter N to confirm.

  34. Enter N to exit.