Setting Session Limits with Web GUI

You can control the maximum number of sessions that are returned when you execute an action. You may want to limit the number of sessions returned if you are concerned that too many sessions may be returned.

Factors Affecting the Number of Sessions Returned

The number of sessions returned in response to a request depends on four factors:

  • The number you type in the Limit Sessions Returned to field. If you leave the field blank, it defaults to the system-wide session limit.
  • The system-wide session limit. This number defaults to 10,000 but may be changed with the assistance of your Juniper Networks Technical Support representative.
  • The Effective Session Limit. This number is always the lesser of the system-wide session limit and the number you enter in the Limit Sessions Returned to field.
  • The number of sessions found that meet the criteria you enter.

Number of Sessions Returned

The number of sessions returned by SBR Carrier is always the lesser of the Effective Session Limit and the number of sessions found that match the criteria you enter.

Table 104 provides examples in which the session limit rules apply.

Table 104: Number of Sessions Found for Various Examples

Value Entered in the “Limit Sessions Returned to” Field

System-Wide Session Limit

Effective Session Limit

Sessions Found

Sessions Returned

Reason

100

10,000

100

200

100

Effective session limit prevails

100

10,000

100

50

50

Number of sessions found is within effective limit

10

10,000

10

200

10

Effective session limit prevails

blank

10,000

10,000

200

200

Number of sessions found is within effective limit

20,000

10,000

10,000

25,000

10,000

Effective session limit prevails