    Installing an AC Power Supply in the MAG6610 and MAG6611

    Before you install an AC power supply in the Junos Pulse Gateway, ensure you understand how to prevent ESD damage.

    Note: Each power supply must be connected to a dedicated power source outlet.

    The power supply in the Junos Pulse Gateway MAG6611 is a hot-removable and hot-insertable field-replaceable unit (FRU) if you have two power supplies already installed: You can remove and replace it without powering off the Junos Pulse Gateway.

    To install a power supply in the Junos Pulse Gateway:

    1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to the ESD point on the chassis.
    2. If the power supply slot has a cover panel on it, pull the handle of the cover panel outwards and remove it. Save the cover panel for later use.
    3. Taking care not to touch power supply pins, leads, or solder connections, remove the power supply from the bag.
    4. Using both hands, place the power supply in the power supply slot on the rear panel of the chassis and slide it in until it is fully seated. You will hear a distinct click sound when the power supply is fully seated in the chassis.

    Figure 1: Installing a Power Supply in the Junos Pulse Gateway

    Image g020832.gif

    Published: 2011-07-25