JCS 1200 Alarm Panel Interface Connector Electrical Specifications

Table 1 lists the electrical specifications for the JCS 1200 alarm panel interface connector.

Table 1: JCS 1200 Alarm Panel Interface Connector Electrical Specifications

Item

Specification

Outputs

Voltage range

0 V DC to –100 V DC (maximum current 0.3 A at 100 V DC)

Current range

0 A to 1 A (maximum voltage 30 V DC at 1 A)

Worst-case VA

1 A at –30 V DC (30 VA maximum) indefinitely

Inputs

Voltage range

0 V DC to –100 V DC (including transients)

Differential input voltage

3 V DC to 72 V DC

Reset Input Activation

Pulse width

200 ms (minimum) to 300 ms

Note: The reset input resets only the state of the relay contact. The chassis alarm status does not change.