Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 

TCX1000-RDM20 Port Alarm Thresholds

 

Table 1 describes the external port alarm threshold values that are programmable through the proNX Optical Director for the TCX1000-RDM20.

Note

Hysteresis value is +/-1.0 dB for all ports and interfaces described in Table 1. Hysteresis values are not user configurable.

Table 1: TCX1000-RDM20 External Port Thresholds

Port

Hardware Alarm

Description

Threshold

(dBm)

Line In

Optical-los

Loss of signal

Range 1: -25.0

Range 2: -36.0

Input-low-degrade

Input Power Degraded

Range 1: -22.0

Range 2: -33.0

Line Out

Optical-loo

Loss of output

-18.2

OSC 0/1 In

Optical-los

Loss of signal

-11

OSC 0/1 Out

Optical-loo

Loss of output

-41.60

Ux In

Optical-los

Loss of signal

-15.65

Input-low-degrade

Input Power Degraded

12.65