TCX1000-RDM20 Connection Alarms and Probable Causes

 

Table 1 describes the connection alarms and their probable causes.

Table 1: Connection Alarms and Probable Causes

Entity

Alarm

Description

Probable Cause/

Probable Location

Severity

Ux In

optical-los

Loss of input on port

Probable-cause-direction="rx"

Probable-cause-location="FAREND"

Major

input-low-degrade

Input channel power degraded

Probable-cause-direction="rx"

Probable-cause-location="FAREND"

Major

input-overload

Input channel power overload

Probable-cause-direction="rx"

Probable-cause-location="FAREND"

Major

optical-loo

Loss of output channel

Probable-cause-direction="tx"

Probable-cause-location="NEAREND"

Major

output-overload

Output channel overload

Probable-cause-direction="tx"

Probable-cause-location="NEAREND"

Major

output-low-degrade

Output channel degraded

Probable-cause-direction="tx"

Probable-cause-location="NEAREND"

Major

Ux Out

optical-los

Loss of input channel

Probable-cause-direction="rx"

Probable-cause-location="FAREND"

Major

input-overload

Input channel power overload

Probable-cause-direction="rx"

Probable-cause-location="FAREND"

Major

input-low-degrade

Input channel power degraded

Probable-cause-direction="rx"

Probable-cause-location="FAREND"

Major