TCX1000-RDM20 Connection Alarm Thresholds

 

Table 1 describes the connection alarm threshold values that are available through the proNX Optical Director for the TCX1000-RDM20.

Note

Hysteresis value for all connection thresholds is +/- 1.0 dB unless otherwise noted. Hysteresis values are not user configurable.

Table 1: TCX1000-RDM20 Connection Thresholds

Connection

Hardware Alarm

Description

Threshold

(dBm)

Ux In

Optical-los

Loss of signal channel

-17.65

Input-overload

Input Channel Power Overload

1.55

Input-low-degrade

Input Channel Power Degraded

-14.65

Optical-loo

Loss of output channel

-26.75

Output-overload

Output Channel Power Overload

-15.75

Output-low-degrade

Output Channel Power Degraded

-23.75

Ux Out

Optical-los

Loss of signal channel

-8.15

Input-overload

Input Channel Power Overload

7.05

Input-low-degrade

Input Channel Power Degraded

-0.95