Elements that You Can Configure in the CLI

To list the elements that you can configure using the CLI, type enable at the prompt and press Enter. Table 35 list the configurable elements that appear.

Table 35: Configurable Elements in the CLI

Command

Description

Supported Users

Disable

Disables privileged access (to configuration commands)

  • Admin
  • Read/Write

config web-timeout

Configures the web-timeout. [min]

  • Admin
  • Read/Write

config hostname

Configures the host name. {hostname}

  • Admin
  • Read/Write

config domain

Configures the domain. {domain name}

  • Admin
  • Read/Write

config eth0 ip-mode

Selects the IP mode for the Ethernet 0 (LAN1) port between Static and DHCP.

  • Admin
  • Read/Write

config eth0 ip

Configures IP settings for Ethernet 0 (LAN1) port : IP address, mask, and gateway.

  • Admin
  • Read/Write

config eth0 speed

Selects the speed for the Ethernet 0 (LAN1) port between 10 and 100Mbps.

  • Admin
  • Read/Write

config eth0 duplex

Selects the duplex mode for the Ethernet 0 (LAN1) port between half or full duplex.

  • Admin
  • Read/Write

config eth0 auto-nego

Turns Auto Negotiation ON or OFF for Ethernet 0 (LAN1) port.

  • Admin
  • Read/Write

config eth1 ip-mode

Selects the IP mode for the Ethernet 1 (LAN2) port between Static and DHCP.

  • Admin
  • Read/Write

config eth1 ip

Configures IP settings for Ethernet 1 (LAN2) port : IP address, mask, and gateway.

  • Admin
  • Read/Write

config eth1 speed

Selects the speed for the Ethernet 1 (LAN2) port between 10 and 100Mbps.

  • Admin
  • Read/Write

config eth1 duplex

Selects the duplex mode for the Ethernet 1 (LAN2) port between half or full duplex.

  • Admin
  • Read/Write

config eth1 auto-nego

Turns Auto Negotiation on or off for Ethernet 1 (LAN2) port.

  • Admin
  • Read/Write

config snr

Selects SNR units between AMU or dBHz.

Note: This command is not available if the TCA8000 and TCA8500 Timing Servers use the Resolution SMT GPS Timing Receiver. The AMU is not an industry standard unit of measurement.

  • Admin
  • Read/Write

config gps anti-jamming

Enables or disables the anti-jamming capability for the Resolution SMT GPS Timing Receiver.

Note: This command is available only if the TCA8000 and TCA8500 Timing Servers use the Resolution SMT GPS Timing Receiver.

  • Admin
  • Read/Write

config alarm-email-receiver

Configures recipients of alarm email notifications

  • Admin
  • Read/Write

config antenna-voltage

Configures the input voltage for the antenna between 3.3 or 5V.

  • Admin
  • Read/Write

config sync-src-priority

Configures the highest priority Sync Source that the Timing Server should use. Choices include: gps, E1, ptp, or internal.

  • Admin
  • Read/Write

config dns0

Configures the primary DNS server IP.

  • Admin
  • Read/Write

config dns1

Configures the second DNS server IP.

  • Admin
  • Read/Write

config password

Modifies your current login password.

Admin

config enable-password

Modifies the password of the enable mode.

Admin

config web

Configures the web enable/disable.

  • Admin
  • Read/Write

config web-mode

Configures the web mode.

  • Admin
  • Read/Write

config timezone

Configures the timezone information.

  • Admin
  • Read/Write

config cli-timeout

Configures the session in-action session timeout.

  • Admin
  • Read/Write

config alarm-profile

Configures the alarm profile.

  • Admin
  • Read/Write

config snmp readwrite-community

Configures the SNMP read and write community.

  • Admin
  • Read/Write

config snmp readonly-community

Configures the SNMP read only community.

  • Admin
  • Read/Write

config snmp contact

Configures the SNMP contact.

  • Admin
  • Read/Write

config ptp add server

Adds a ptp server.

  • Admin
  • Read/Write

config snmp-v3user add

Adds a SNMP v3 user.

  • Admin
  • Read/Write

config snmp-v3user del

Deletes a SNMP v3 user.

  • Admin
  • Read/Write

config snmp-trap add

Adds a trap receiver address to the list.

  • Admin
  • Read/Write

config snmp-trap del

Deletes a trap receiver from the list.

  • Admin
  • Read/Write

config language

Configures the web pages language.

  • Admin
  • Read/Write

config e1 output port

Configures the E1 output port’s number of ports, mode, framing, encoding, LBO, SSM, and state.

  • Admin
  • Read/Write

config e1 output loopback

Configures the E1 input port’s number of ports, mode, framing, encoding, Receive Sensitivity, SSM, and state.

  • Admin
  • Read/Write

config 1/5MHz

Selects between 1MHz vs. 5MHz output on the 1/5MHz port.

  • Admin
  • Read/Write

config irig-b

Configures modes for the IRIG-B output port.

  • Admin
  • Read/Write

config ptp grandmaster

Configures PTP grandmaster settings: profile selection, 1- vs. 2- step, Sync, Delay Request, and Announcement Packet intervals.

  • Admin
  • Read/Write

config ptp gm disable

Disables the PTP protocol.

  • Admin
  • Read/Write

config ptp gm enable

Enables the PTP protocol.

  • Admin
  • Read/Write

config ptp gm dscp

Configures the Differential Service (DiffServ) of the IP packet, which transports the PTP event and signaling messages.

  • Admin
  • Read/Write

config ptp unicast add

Adds the IP address of a Timing Client (Slave) through which the Grandmaster sends or receives event messages.

  • Admin
  • Read/Write

config ptp unicast del

Deletes the IP address of a Timing Client (Slave) through which the Grandmaster sends or receives event messages.

  • Admin
  • Read/Write

clear all-unicast-entry

Clears all the Timing Clients IP addresses.

  • Admin
  • Read/Write

config ptp unicast continuous

Configures the Grandmaster to continuously send the ARP messages to the unicast IP addresses in its Unicast table.

  • ON—Sends an ARP request for every 2 minutes per Timing Client.
  • OFF—Sends ARP requests until the Grandmaster receives the ARP response from the Timing Client and then does not send the ARP requests again until either the Grandmaster is reset or the IP address is deleted and added back.
  • Admin
  • Read/Write

config ptp gm profile

Configures the PTP profile type as Telecom Profile, which is the same profile type value as used for Telecom Profile without Signaling.

  • Admin
  • Read/Write

config ptp gm domain

Configures the PTP domain number for the Timing Client.

  • Admin
  • Read/Write

config ptp gm priority1

Provides a priority value for the Priority 1 parameter, which is used in the Best Master Clock (BMC) algorithm. The value is assigned to assist the BMC to select a Grandmaster for the PTP domain.

  • Admin
  • Read/Write

config ptp gm priority2

Provides a priority value for the Priority 2 parameter, which is used in the BMC algorithm. The value is assigned to assist the BMC to select a Grandmaster for the PTP domain.

  • Admin
  • Read/Write

config ptp gm two-step

Enables the One-Step or Two-Step clock.

  • 0—Enables the One-Step clock.
  • 1—Enables the Two-Step clock.
  • Admin
  • Read/Write

config ptp unicast sync-int-range

Configures the range for Sync event message rate.

  • Admin
  • Read/Write

config ptp unicast delay-int-range

Configures the range for delay request or response event message rate.

  • Admin
  • Read/Write

config ptp unicast announce-int-range

Configures the range for announce interval message rate.

  • Admin
  • Read/Write

config ptp gm announce-receipt-timeout

Configures the timeout period for the announce event messages.

  • Admin
  • Read/Write

config telecom-standard

Configures the telecom standard for the telecom profile. The PTP grandmaster announces the clock class based on the configured telecom standard. The values are:

  • 1 (Default value) - Telecom standard is set as Telecom-IEEE1588.
  • 2 - Telecom standard is set as Telecom-G8265.1-option 1.
  • 3 - Telecom standard is set as Telecom-G8265.1-option 2.
  • 4 - Telecom standard is set as Telecom-G8275.1.

Note: The telecom standard can be configured only for the telecom profile. For other profiles, the default value is set and you cannot configure the telecom standard.

  • Admin
  • Read/Write

config datetime

Configures date and time for the Timing Server.

  • Admin
  • Read/Write

config holdover-state

Configures the TCA system to remain in the holdover state or change to the internal state after 24 hours of holdover state.

  • 1—The system remains in the holdover state instead of changing to the internal state after 24 hours of holdover state. However, the system changes to the internal state when the signal is lost during acquisition, locking, or resetting the system.
  • 0 (default)—The system changes to the internal state after 24 hours of holdover state.
  • Admin
  • Read/Write

config radius-server add

Adds the IP address of the RADIUS authentication server and sets other related configurations (secret word, retries, timeout, and port) to be used by the Timing Server for user authentication.

  • Admin
  • Read/Write

config radius-server del

Deletes the RADIUS authentication server and its configuration from the authentication server list by using the IP address of the authentication server.

  • Admin
  • Read/Write

config auth-order

Configures the authentication order to be followed by the Timing Server while authenticating an user. The following combination of authentication order is allowed:

  • RADIUS server authentication and then local authentication
  • Local authentication and then RADIUS server authentication
  • Only RADIUS server authentication
  • Only local authentication
  • Admin
  • Read/Write

config accounting-server add

Adds the IP address of the RADIUS accounting server and sets other related configurations (secret word, retries, timeout, and port) to be used by the Timing Server for accounting.

  • Admin
  • Read/Write

config accounting-server del

Deletes the RADIUS accounting server and its configuration from the accounting server list by using the IP address of the accounting server.

  • Admin
  • Read/Write

config accounting-level

Configures the information to be used by the Timing Server for accounting. The values are:

  • 1—For login accounting only
  • 2—For interactive and login accounting
  • 3—For configuration, interactive and login accounting
  • Admin
  • Read/Write

config accounting

Enables or disables RADIUS accounting in the Timing Server.

  • Admin
  • Read/Write

config user add

Creates a new user account with login class as Read-Only or Read/Write.

Admin

config user del

Deletes the Read-Only or Read/Write user account.

Admin

config user password

Creates a new password for the Read-Only or Read/Write user account.

Admin

config user class

Modifies the login class for the Read-Only or Read/Write user account.

Admin

config change-password

Modifies your current login password.

Read/Write

reset password

Restores the default password value.

Admin

reset config

Restores the Timing Server to the manufacturer default configuration.

Admin

reboot

Reboots the system.

  • Admin
  • Read/Write

halt

Halts the system.

  • Admin
  • Read/Write

ping

Pings the remote host.

  • Admin
  • Read/Write

tftp

Installs a software upgrade image file by TFTP

  • Admin
  • Read/Write

save daemonlog

Saves the daemon log to a TFTP server.

  • Admin
  • Read/Write

save syslog

Saves the system log to a TFTP server.

  • Admin
  • Read/Write

save authlog

Saves the author log to a TFTP server.

  • Admin
  • Read/Write

save eventlog

Saves the event log to a TFTP server.

  • Admin
  • Read/Write

backup

Backs up the configuration file to a TFTP server.

  • Admin
  • Read/Write

restore

Restores the configuration file to a TFTP server.

  • Admin
  • Read/Write

clear alarm

Clears the alarm.

  • Admin
  • Read/Write

alarm-cut-off

Cuts off audio alarms.

  • Admin
  • Read/Write

tftp license

Upload TFTP license for value-added features.

  • Admin
  • Read/Write

clear daemon log

Clears daemon log.

  • Admin
  • Read/Write

clear syslog

Clears system log.

  • Admin
  • Read/Write

clear eventlog

Clears event log.

  • Admin
  • Read/Write

clear authlog

Clears authorization log.

  • Admin
  • Read/Write