A
- admin page
- agency compliance
- alarms
- antenna
- mounting
- mounting conditions 1, 2
- mounting requirements
B
C
- clear alarm command
- clear authlog command
- clear daemon log command
- clear eventlog command
- clear ptp-stat command
- clear syslog command
- CLI 1
- commands
- backup scp
- backup tftp
- clear alarm
- clear authlog
- clear daemon log
- clear eventlog
- clear ptp-stat
- clear syslog
- config 1/5MHz
- config accounting
- config accounting-level
- config accounting-server add
- config accounting-server del
- config alarm-email-receiver
- config alarm-profile
- config antenna-cable-delay-compensation
- config antenna-voltage
- config auth-order
- config change-password
- config cli-banner-file
- config cli-banner-text
- config cli-timeout
- config datetime
- config dns0
- config dns1
- config domain
- config dst
- config e1 output loopback
- config e1 output port
- config enable-password
- config eth0 auto-nego
- config eth0 duplex
- config eth0 ip
- config eth0 ip-mode
- config eth0 speed
- config gps anti-jamming
- config holdover-state
- config hostname
- config language
- config password
- config pps-squelch
- config ppx
- config primary-ptp-server
- config ptp add server
- config ptp slave
- config radius-server add
- config radius-server del
- config secondary-ptp-server
- config snmp contact
- config snmp readonly-community
- config snmp readwrite-community
- config snmp-trap add
- config snmp-trap del
- config snmp-v3user add
- config snmp-v3user del
- config snr
- config ssl-cert
- config ssl-key
- config sync-src-priority
- config timezone
- config unsecured-communication-protocols
- config user add
- config user class
- config user del
- config user password
- config web
- config web-mode
- config web-timeout
- ftp
- halt
- ping
- reboot
- reset config
- reset password
- restart ptp
- restart timeprobe-agent
- restore scp
- restore tftp
- save scp authlog
- save scp daemonlog
- save scp eventlog
- save scp syslog
- save tftp authlog
- save tftp daemonlog
- save tftp eventlog
- save tftp syslog
- scp
- tftp
- tftp license
- compliance
- config 1/5/10MHz command
- config accounting
- config accounting-level
- config accounting-server add
- config accounting-server del
- config alarm-email-receiver command
- config alarm-profile command
- config antenna-cable-delay-compensation command
- config antenna-voltage command
- config auth-order
- config change-password
- config cli-banner-file
- config cli-banner-text
- config cli-timeout command
- config datetime command
- config dns0 command
- config dns1 command
- config domain command
- config dst command
- config e1 output loopback command
- config e1 output port command
- config enable-password command
- config eth0 auto-nego command
- config eth0 duplex command
- config eth0 ip command
- config eth0 ip-mode command
- config eth0 speed command
- config gps anti-jamming command
- config holdover-state
- config hostname command
- config language command
- config page
- config password command
- config pps-squelch
- config ppx command
- config primary-ptp-server command
- config ptp add server command
- config ptp slave command
- config ptp slv disable command
- config ptp slv domain command
- config ptp slv dscp command
- config ptp slv enable command
- config ptp slv profile command
- config ptp unicast acc-master add command
- config ptp unicast acc-master del command
- config ptp unicast announce command
- config ptp unicast delay command
- config ptp unicast duration command
- config ptp unicast signaling command
- config ptp unicast sync command
- config radius-server add
- config radius-server del
- config secondary-ptp-server command
- config snmp contact command
- config snmp readonly-community command
- config snmp readwrite-community command
- config snmp-trap add command
- config snmp-trap del command
- config snmp-v3user add command
- config snmp-v3user del command
- config snr command
- config ssl-cert command
- config ssl-key command
- config sync-src-priority command
- config timezone command
- config unsecured-communication-protocols command
- config user add
- config user class
- config user del
- config user password
- config web command
- config web-mode command
- config web-timeout command
- console cable
- conventions
- customer support 1, 2
D
E
- e-mail lists
- elements
- EMC testing
- enable mode password
- environmental specifications
- event states
F
- factory defaults
- ftp command
G
- graphical user interface
H
- halt command
- hardware
- height
- humidity
I
- input voltage
- installation instructions
- installation requirements
- IP address
K
L
- log page
- login class
- changing by Admin user
- login page
M
N
P
- parameters
- password
- physical dimensions
- ping command
- port LEDs
- power
- PTP
R
S
- safety testing
- save scp authlog command
- save scp daemonlog command
- save scp eventlog command
- save scp syslog command
- save tftp authlog command
- save tftp daemonlog command
- save tftp eventlog command
- save tftp syslog command
- scp command
- SNMPv3
- software
- specifications
- SSH
- status page
- support
- support, technical See technical support
- system LEDs
T
U
- unpacking the chassis
- upgrading See software
- user account
- admin password changing
- admin password reset
- creating Read-Only user
- creating Read/Write user
- deleting Read-Only user
- deleting Read/Write user
- guidelines
- management
- modifying
- overview
- Read-Only user password changing by Admin user
- Read/Write user password changing by Admin user
- Read/Write user password changing by Read/Write user
- user interface
W
Troubleshooting the TCA6000 or TCA6500 Timing Client Using the Event Log
Use Table 33 to identify which actions to perform when an event is reported in the event log.
Table 33: Troubleshooting the TCA6000 or TCA6500 Timing Client Using the Event Log
Event | Type | Description | Action |
---|---|---|---|
SYS_CONFIG_CHANGE | Static | One or more parameters were changed in the Config menu. | Verify changes were as expected. |
SYS_AUTHENTICATION | Static | The was a failed Login / Password attempt in the unit. | Verify Login name and Password. |
GPS_ANTENNA_SHORT | Transient | Antenna connection is shorted between the Cable Conductor Pin and Shield. | For TCA6500 only, check for a cable short on the center and ground shield. |
GPS_ANTENNA_OPEN | Transient | Cable Connection has an open in it. | For TCA6500 only, check for a cable open on the center and ground shield. |
GPS_NO_USABLE_SATELLITE | Transient | The antenna is unable to acquire any satellites with sufficient signal levels. | For TCA6500 only:
|
GPS_LEAP_SECOND_PENDING | Transient | GPS notifies of this event approximately 3 months before event. | For TCA6500 only:
|
GPS_RECEIVER_INACTIVE | Transient | Internal communication to the GPS Receiver failed to respond. | For TCA6500 only:
|
TIMING_OSC_DAC_RANGE | Transient | The Digital-to-Analog Converter (DAC) which controls the voltage adjustment for the Oscillator frequency has exceeded its range of control voltage. | Verify operational temperature is within specification of the unit. |
OVEN_TEMP_DEVIATION_HIGH | Transient | Secondary oscillator Oven Temperature increase was faster than the internal oven control could compensate. | This is status only information as the internal oscillator oven temperature control will eventually compensate for this. |
OVEN_TEMP_DEVIATION_LOW | Transient | Secondary oscillator Oven Temperature decrease was faster than the internal oven control could compensate. | This is status only information as the internal oscillator oven temperature control will eventually compensate for this. |
SYS_DIAG_FAILURE | Transient | The boot-up System Diagnostics had one or more failures. |
|
PTP_SERVER_UNREACHABLE | Transient | There is no master PTP Grand Master available in the network for the configured domain number. |
|
PTP_SERVER_CHANGE | Static | A Best Master selection has occurred and the server was changed. | Verify the "other" master had an abnormal event that caused this event. |
LOSS_OF_POWER_FEED | Transient | One of the DC inputs has no voltage connected. |
|
FREQ_ACQUIRING | Transient | System tries to adjust the local oscillator based on the input source such as GPS, T1, E1, and PTP. If the adjustments are completed, then the system state is changed from acquiring state to locked state. | This is a positive indication of sync source availability. |
FREQ_HOLDOVER | Transient | Local Oscillator is in Holdover state. There is no configured servers sync sources available. Only goes to this state after a sync source has been qualified for a period of time and than is not available. | Check sync source quality which was configured in the sync source table. |
FREQ_FREERUN | Transient | Local Oscillator is in Freerun state. The unit has not obtained initial lock sync lock state and is operating on the local oscillator. |
|
FREQ_REF_INPUT_CHANGE | Static | The reference input being used as a sync source has changed. | Verify one of the reference input such as GPS, external inputs has changed. |
FREQ_INPUT_QUALITY_CHANGE | Static | The timing input quality has changed due to lower or higher quality level of the new sync source. | Verify the quality states changes were as expected. |
LINK_DOWN | Static | Ethernet connection is not functional. | Verify Ethernet connection, cables, and so on. |
LINK_UP | Static | Ethernet connection is functional. | This is a positive indication of the Ethernet link status. To suppress go to Configure Admin > Alarm > Severity and set to NONE. |
TIMEPROBE_DISABLE | Transient | The time probe agent is disabled or accidentally turned off. | Start or enable the time probe agent using the restart timeprobe-agent command. |