Configuring Alarms
How the TCA6000 or TCA6500 Timing Client handles alarms during normal operation can be specified. To configure the alarms:
- Click the Admin tab. The Admin page appears.
- Click the Alarm Profile tab. See Figure 8.
- For each alarm, the following parameters can be configured:
- Select the Clear Now check box to clear an alarm immediately. This only applies to non-transient (box gray filled) and not transient alarms.
- Select the Auto Clear check box to clear an alarm automatically after it has been active for the Auto Clear Expiration period of 1-24 hours. This only applies to non-transient (box gray filled) and not transient alarms.
- In the Severity field, select
the flag to accompany this alarm. Select:Critical
— Indicates the highest level alarm and is severely affecting traffic. This needs immediate attention. The following alarms are directly related to this level:
TE1_LOS, TE1_LOF, FREQ_FREERUN, LINK_DOWN
Major— Indicates this alarm needs immediate attention. The following alarms are recommended for this level:
PTP_SERVER_UNREACHABLE, LOSS_OF_POWER_FEED, FREQ_HOLDOVER
Minor— Indicates this alarm needs attention but is not urgent. The following alarms are recommended for this level:
SYS_CONFIG_CHANGE, TE1_AIS, TE1_RAI, PTP_SERVER_CHANGE, FREQ_REF_INPUT_CHANGE, FREQ_INPUT_QUALITY_CHANGE, LINK_DOWN, TIMING_OSC_DAC
None— Indicates this alarm is for information only. The following alarms are recommended for this level:
SYS_AUTHENTICATION, OVEN_TEMP_DEVIATION_HIGH, OVEN_TEMP_DEVIATION_LOW, LINK_UP, TIMEPROBE_DISABLE, FREQ_ACQUIRING
- Select the Send Trap check box. The Timing Client will send the alarm to the Trap destinations identified on the Config page.
- Select the Write Log check box. The Timing Client will send the alarm to the local log file.
- Select the Send to Email check box. The Timing Client will send an e-mail message about this alarm to the users identified in the Alarm E-mail Recipients section of the Alarm tab.