    Verification

    The following verification commands (with sample output) can be used to confirm that the SRX chassis cluster is configured properly.

    Results

    1. Verify chassis cluster configuration.
      root@vdc-edge-fw01-n0> show chassis cluster status
      Cluster ID: 1 
      Node                  Priority          Status    Preempt  Manual failover
      
      Redundancy group: 0 , Failover count: 1
          node0                   129         primary        no       no  
          node1                   128         secondary      no       no  
      
      Redundancy group: 1 , Failover count: 1
          node0                   129         primary        no       no  
          node1                   128         secondary      no       no  
      