Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All

    Display the Redundant SSB Environmental Status

    Purpose

    To obtain the environmental status of the redundant SSB.

    Action

    To display the SSB environmental status, use the following command:

    user@host> show chassis environment

    Sample Output

    user@host> show chassis environment
    Class Item                   Status     Measurement
    Power Power Supply A         Failed    
          Power Supply B         OK        
    Temp  FPC Slot 0             OK         27 degrees C / 80 degrees F
          FPC Slot 1             OK         30 degrees C / 86 degrees F
          FPC Slot 2             OK         26 degrees C / 78 degrees F
          FPC Slot 3             OK         25 degrees C / 77 degrees F
          Power Supply A         OK         28 degrees C / 82 degrees F
          Power Supply B         OK         24 degrees C / 75 degrees F
          SSB Slot 0             OK         25 degrees C / 77 degrees F
          Backplane              OK         21 degrees C / 69 degrees F
    Fans  Rear Fan               OK         Spinning at normal speed
          Upper Fan              OK         Spinning at normal speed
          Middle Fan             OK         Spinning at normal speed
          Bottom Fan             OK         Spinning at normal speed
    Misc  Craft Interface        OK        
    

    Meaning

    The command output displays the SSB status and temperature. The SSB status can be OK, Failed, or Absent.

    Published: 2012-08-20