    Check M40e Router Redundant SFM Configuration

    Purpose

    You can configure which SFM is the master and which is the backup. By default, the SFM in slot 0 is the master and the SFM in slot 1 is the backup. You can modify the default configuration by including the sfm statement at the [edit chassis redundancy] hierarchy level.

    Note: We recommend that both Routing Engines have the same configuration.

    Action

    To display the current SFM redundancy configuration:

    1. Enter configuration mode using the following command:
      user@host# configure
    2. Go to the [edit chassis redundancy] hierarchy level.
    3. Show the SFM configuration using the following command:
      user@host# show
     