Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Related Documentation
- M Series
- Checklist for Monitoring the SCG
- T Series
- Checklist for Monitoring the SCG
Display the SCG LED States at the Command Line
Purpose
To display the SCG LED states.
Action
To display the SCG LED states, use the following command:
user@host> show chassis craft-interface
Sample Output
t320@host> show chassis craft-interface [...Output truncated...] SCG LEDs: SCG 0 1 -------------- Amber . . Green * * Blue * . [...Output truncated...]
Meaning
The command output displays the SCG LED status. The router has two SCGs installed. Asterisks (*) indicate the operation status. The color represents the possible SCG operating states: Amber (Fail), Green (OK), and Blue (Master). Both SCGs are functioning properly (Green). The SCG in slot 0 is operating as master; the SCG in slot 1 is the backup.
Related Documentation
- M Series
- Checklist for Monitoring the SCG
- T Series
- Checklist for Monitoring the SCG