    Display the Replaced PCG Environmental Status

    Purpose

    To verify if the replaced PCG is online by checking the PCG environmental status.

    Action

    To verify that the replaced PCG is online, use the following command:

    user@host> show chassis environment pcg

    Sample Output

    user@host> show chassis environment pcg
    PCG 0 status:
       State                           Online
       Temperature                  30 degrees C / 86 degrees F
       Frequency:
         Setting                125.00 MHz
         Measurement            125.01 MHz
       Power:
         3.3 V                    3278 mV
         5.0 V bias               4986 mV
         8.0 V bias               8222 mV
       CMB Revision                 12
    PCG 1 status:
       State                           Online - PFE clock source
       Temperature                  43 degrees C / 109 degrees F
       Frequency:
         Setting                125.00 MHz
         Measurement            124.95 MHz
       Power:
         3.3 V                    3269 mV
         5.0 V bias               4991 mV
         8.0 V bias               8222 mV
       CMB Revision                 12
    

    Meaning

    When the replaced PCG is brought online, it does not automatically become master. It remains as the backup PCG until the master PCG fails, or you manually switch it to master by using the request chassis pcg online slot 1 command.

     