Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Display PCG Error Messages in the Chassis Daemon Log File
Purpose
To determine the details of the PCG error messages in the chassis daemon log file.
Action
To display the PCG error messages in the chassis daemon (chassisd) log file and verify that a replaced PCG is online, use the following command:
user@host> show log chassisd | match PCG
Sample Output
user@host> show log chassisd | match PCG
Aug 27 15:20:51 PCG 0 power verified on in 16 ms Aug 27 15:20:52 reading PCG 0 initial state Aug 27 15:20:52 CMB readback PCG 0 [0xe2, 0xff] -> 0xc Aug 27 15:20:52 reading PCG 0 ideeprom Aug 27 15:20:52 CMB cmd to PCG 0 [0xe2], Green LED On [0x1b] Aug 27 15:20:52 PCG 0 - Green LED On Aug 27 15:20:52 PCG 0 clear alarm 0x3 Aug 27 15:20:52 alarm op fru 1 op 0 reason 3 Aug 27 15:20:52 send: yellow alarm clear, class 100 obj 110 reason 3.
Meaning
The chassisd database provides the date, time, and a component status message. The chassisd database is dynamic. It is initialized at router startup and is updated when components are added or removed.