    Display PCG Error Messages in the Chassis Daemon Log File

    Purpose

    To determine the details of the PCG error messages in the chassis daemon log file.

    Action

    To display the PCG error messages in the chassis daemon (chassisd) log file and verify that a replaced PCG is online, use the following command:

    user@host> show log chassisd | match PCG

    Sample Output

    user@host> show log chassisd | match PCG
    Aug 27 15:20:51 PCG 0 power verified on in 16 ms
    Aug 27 15:20:52 reading PCG 0 initial state
    Aug 27 15:20:52 CMB readback PCG 0 [0xe2, 0xff] -> 0xc
    Aug 27 15:20:52 reading PCG 0 ideeprom
    Aug 27 15:20:52 CMB cmd to PCG 0 [0xe2], Green LED On [0x1b]
    Aug 27 15:20:52 PCG 0 - Green LED On
    Aug 27 15:20:52 PCG 0 clear alarm 0x3
    Aug 27 15:20:52 alarm op fru 1 op 0 reason 3
    Aug 27 15:20:52 send: yellow alarm clear, class 100 obj 110 reason 3.
    

    Meaning

    The chassisd database provides the date, time, and a component status message. The chassisd database is dynamic. It is initialized at router startup and is updated when components are added or removed.

     