Display PCG Error Messages in the Chassis Daemon Log File
Purpose
To determine the details of the PCG error messages in the chassis daemon log file.
Action
To display the PCG error messages in the chassis daemon (chassisd) log file, use the following command:
user@host> show log chassisd
Sample Output
user@host> show log chassisd
Jun 11 20:31:17 FPC 7 - Disable Power [addr 0x17 cmd 0x10] Jun 11 20:31:17 CMB readback FPC 7 [0xf7, 0xf2] -> 0x26 Jun 11 20:31:17 power disable verified, FPC 7 Jun 11 20:31:17 CHASSISD_IFDEV_DETACH: ifdev_detach(7) Jun 11 20:31:17 ifd so-7/0/0 marked as gone Jun 11 20:31:19 PCG 0 set alarm 0x3 Jun 11 20:31:19 alarm op fru 1 op 1 reason 3 Jun 11 20:31:19 send: yellow alarm set, class 100 obj 110 reason 3 Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Disable Power [0x10] Jun 11 20:31:19 PCG 0 - Disable Power [addr 0x2 cmd 0x10] Jun 11 20:31:19 CMB readback PCG 0 [0xe2, 0xf2] -> 0x6 Jun 11 20:31:19 power disable verified, PCG 0 Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Blue LED Off [0x16] Jun 11 20:31:19 PCG 0 - Blue LED Off Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Green LED Off [0x1a] Jun 11 20:31:19 PCG 0 - Green LED Off Jun 11 20:31:19 CMB cmd to PCG 0 [0xe2], Amber LED Off [0x18] Jun 11 20:31:19 PCG 0 - Amber LED Off Jun 11 20:31:19 mcs_intr_handler fpm_mcsfd 10 Jun 11 20:31:19 mcs_intr mcs_ints_pending 0x7cbf20 button_status 0x0 Jun 11 20:31:19 bp_handle_button_intr button status 0x0 Jun 11 20:31:21 reading FPC 0 initial state Jun 11 20:31:21 CMB readback FPC 0 [0xf0, 0xff] -> 0xc Jun 11 20:31:21 reading FPC 0 ideeprom Jun 11 20:31:21 reading FPC 1 initial state Jun 11 20:31:21 CMB readback FPC 1 [0xf1, 0xff] -> 0xc Jun 11 20:31:21 reading FPC 1 ideeprom Jun 11 20:31:21 reading FPC 2 initial state Jun 11 20:31:21 CMB readback FPC 2 [0xf2, 0xff] -> 0xc Jun 11 20:31:21 reading FPC 2 ideeprom Jun 11 20:31:21 reading FPC 6 initial state Jun 11 20:31:21 CMB readback FPC 6 [0xf6, 0xff] -> 0xc Jun 11 20:31:21 reading FPC 6 ideeprom Jun 11 20:31:21 reading FPC 7 initial state Jun 11 20:31:21 CMB readback FPC 7 [0xf7, 0xff] -> 0xc Jun 11 20:31:21 reading FPC 7 ideeprom Jun 11 20:31:21 gen_sfm_wait_mask 0x0 Jun 11 20:31:21 ...power sequencer started...
Meaning
The chassisd database provides the date, time, and a component status message. The chassisd database is dynamic. It is initialized at router startup and is updated when components are added or removed.