Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation
Guide That Contains This Content
[+] Expand All
[-] Collapse All
     

    Related Documentation

     

    Display FIC Status at the Command Line

    Purpose

    To display the FIC status at the command line.

    Action

    To display the FIC status, use the following command:

    user@host> show chassis pic pic-slot 3 fpc-slot 1

    Sample Output

    user@host> show chassis pic pic-slot 3 fpc-slot 1
    PIC fpc slot 1 pic slot 3 information:
      Type                             1x G/E, 1000 BASE
      ASIC type                        QGE FPGA
      State                            Online    
      PIC version                  1.4
      Uptime                        12 hours, 11 minutes, 39 seconds
    PIC Port Information:
      Port        Cable             SFP                SFP Vendor
      Number      Type              Vendor Name        Part Number
      0           UNKNOWN CABLE 
    

    Meaning

    Since the FIC is located in FPC 1 slot 3, you must specify its location with the show chassis pic command. The command output displays the FIC information, such as the FIC type, ASIC type, operating status, PIC version, and the amount of time the FIC has been online. The command output also displays port cable information.

     