    Check the CFEB Uptime

    Purpose

    To check the CFEB uptime. A short uptime can indicate a CFEB failure.

    Action

    To check the CFEB uptime, use the following command:

    user@host> show chassis cfeb

    Sample Output

    user@host> show chassis cfeb
    CFEB status:
    Slot 0 information:
      State                                 Master
      Intake temperature                 29 degrees C / 84 degrees F
      Exhaust temperature                38 degrees C / 100 degrees F
      CPU utilization                     3 percent
      Interrupt utilization               0 percent
      Heap utilization                   10 percent
      Buffer utilization                 22 percent
      Total CPU DRAM                    128 MB
      Internet Processor II                 Version 1, Foundry IBM, Part number 164
      Start time:                           2004-09-28 03:07:54 PDT
      Uptime:                              9 days, 18 hours, 41 minutes, 32 seconds
    Slot 1 information:
      State                                 Backup
    

    Meaning

    The command output displays how long the CFEB has been operating. A short uptime can indicate a CFEB failure. Look for error messages that were generated at least 5 minutes prior to the failure event by using the following command:

    user@host> show log messages | match cfeb
     

    Related Documentation

     

    Published: 2012-08-20