    Problem

    A PIC LED lit red indicates a problem with the PIC.

    Solution

    To troubleshoot a PIC:

    1. Check the status of each port on a PIC. Look at the LEDs located on the PIC faceplate. For information about the meaning of LED states on different PICs, see the PTX Series Packet Transport Switch PIC Guide PDF Document.
    2. Check the status of a PIC, issuing the following CLI command. The PIC slots in the FPC are numbered from 0 through 2, top to bottom:
      user@host> show chassis fpc pic-status
      user@host> show chassis fpc pic-status
      Slot 0   Online       FPC
      Slot 2   Online       FPC
        PIC 0  Online       24x 10GE(LAN) SFP+
      Slot 3   Online       FPC
        PIC 1  Online       SNG Load
      Slot 5   Online       FPC
        PIC 0  Online       24x 10GE(LAN) SFP+
        PIC 1  Online       2x 40GE CFP
      Slot 6   Online       FPC
      Slot 7   Online       FPC
      
      user@host> show chassis pic fpc-slot 2 pic-slot 0
      FPC slot 2, PIC slot 0 information:
        Type                             24x 10GE(LAN) SFP+
        State                            Online
        PIC version                 1.14
        Uptime                         3 hours, 6 minutes, 30 seconds
      
      PIC port information:
                                Fiber                    Xcvr vendor
        Port  Cable type        type  Xcvr vendor        part number       Wavelength
        0     10GBASE SR        MM    SumitomoElectric   SPP5200SR-J6-M    850 nm
        1     10GBASE LR        SM    FINISAR CORP.      FTLX1471D3BNL-J1  1310 nm
        3     10GBASE LR        SM    FINISAR CORP.      FTLX1471D3BNL-J1  1310 nm
        6     10GBASE SR        MM    OPNEXT, INC.       TRS2001EM-0014    850 nm
        7     10GBASE SR        MM    OPNEXT, INC.       TRS2001EM-0014    850 nm
        10    10GBASE SR        MM    SumitomoElectric   SPP5200SR-J6-M    850 nm
        11    10GBASE SR        MM    FINISAR CORP.      FTLX8571D3BNL-J1  850 nm
        12    10GBASE SR        MM    SumitomoElectric   SPP5200SR-J6-M    850 nm
        14    10GBASE SR        MM    SumitomoElectric   SPP5200SR-J6-M    850 nm
        15    10GBASE SR        MM    FINISAR CORP.      FTLX8571D3BNL-J1  850 nm
        16    10GBASE SR        MM    FINISAR CORP.      FTLX8571D3BNL-J1  850 nm
        19    10GBASE LR        SM    OPNEXT,INC         TRS5020EN-S201    1310 nm
        21    10GBASE SR        MM    FINISAR CORP.      FTLX8571D3BNL-J1  850 nm
        22    10GBASE LR        SM    FINISAR CORP.      FTLX1471D3BNL-J1  1310 nm
        23    10GBASE SR        MM    FINISAR CORP.      FTLX8571D3BNL-J1  850 nm
      