Troubleshooting the TX Matrix Craft Interface

 

Problem:

Description:

The following alarms and command output indicate a problem with the craft interface:

  • An alarm indicates that the craft interface has failed as shown in Table 1.

  • The show chassis environment fpm sfc 0 indicates that the craft interface is Offline.

  • The show chassis craft-interface displays no output.

Solution

  1. Use the show chassis environment fpm sfc 0 command to verify that the state of the craft interface is online.
    user@host> show chassis environment fpm sfc 0
  2. Use the show chassis craft-interface command to verify that the craft interface is returning information about the chassis.
    • If no information is returned in the output, make sure that the command was issued from the master Routing Engine. If the command was issued to the master Routing Engine, the craft interface has failed, and should be replaced.

    • If the some output is displayed, but no output is shown for the LCD, the LCD has failed. Replace the craft interface.

Table 1 shows alarm messages for the craft interface. The text in the column labeled ”LCD Message” appears in the display of the craft interface. The text in the column labeled “CLI Message” appears in the output from the show chassis alarms command.

Table 1: Craft Interface Alarm Message

Alarm Type

LCD Message

CLI Message

Alarm Condition

Recovery

Yellow

Not Applicable

Craft Failure

The craft interface has failed.

Make sure the craft interface is properly seated.

Replace the craft interface.