Troubleshooting the System I/O Card on the SRX1400 Services Gateway
To troubleshoot a SYSIOC , follow these guidelines:
Make sure the SYSIOC is properly seated in the slot and its screws are tightened.
Use the CLI show chassis fpc command to check the status of the installed SYSIOC. As shown in the sample output, the value Online in the column labeled State indicates that the SYSIOC is functioning normally:
user@host> show chassis fpc 0
Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 41 40 0 1024 3 27
Use the CLI show chassis fpc 0 detail command for more detailed output.
user@host> show chassis fpc 0 detail
Slot 0 information: State Online Temperature 41 degrees C / 105 degrees F Total CPU DRAM 1024 MB Total RLDRAM 0 MB Total DDR DRAM 0 MB Start time: 2010-07-08 13:56:19 UTC Uptime: 5 days, 20 hours, 7 minutes, 49 seconds Max Power Consumption 0 Watts
For further descriptions of the output from the commands, see the Junos System Basics and Services Command Reference.