Taking a Switching Data Plane Offline

 
  1. Issue the show chassis fabric plane-location command to identify the switching plane affected by the replacement or maintenance procedure. For example, the F13 SIB in slot 6 resides in switching plane 2. The corresponding F2 SIBs are 2/0, 2/2, 2/4, 2/6.
    user@host> show chassis fabric plane-location
  2. Determine if the component resides in an active switching plane and verify that there is a spare plane by issuing the show chassis fabric plane detail command:
    user@host> show chassis fabric plane detail
  3. Take the TXP-F13 SIB residing in an active switching plane offline by issuing the request chassis fabric plane plane-number offline all-chassis command. For example:
    user@host> request chassis fabric plane 2 offline all-chassis
  4. After you have finished the replacement or maintenance procedure, issue the request chassis fabric plane plane-number online all-chassis command to put the switching plane into the spare state. For example:
    user@host> request chassis fabric plane 2 online all-chassis
  5. Issue the show chassis fabric plane detail command to confirm that the switching plane is in the spare state.
    user@host> show chassis fabric plane detail